English

English

Get a Quote
Products

Hot Products

Company News

Three Common Causes of Valve Leakage and Emergency Remedies
Three Common Causes of Valve Leakage and Emergency Remedies
2025-05-28

In industrial production, valves are critical components for fluid control, and their sealing performance directly impacts system safety and stability. Leakage not only reduces operational efficiency but may also lead to fluid escape, posing serious safety risks. This article outlines three common causes of valve leakage and provides corresponding emergency response recommendations to help you quickly identify issues, take action, and mitigate risks.   1. Seal Surface Wear or Damage   Cause: During long-term operation, sealing pairs (e.g., valve seat and disc, valve ball and seat) suffer from media erosion, particle abrasion, or corrosion, leading to uneven sealing surfaces and resulting in minor or significant leakage. Emergency Measures: · Minor Leakage: Adjust compression force (e.g., tighten bonnet bolts) to temporarily reduce leakage. · Severe Leakage: Immediately shut down the system to replace or regrind sealing components; replace the entire valve if necessary. Prevention Recommendations: Conduct regular inspections, select valves with appropriate materials and wear-resistant designs. For media containing solid particles, use hard-sealing structures.   2. Packing Aging or Gland Loosening   Cause: Valve stem sealing uses packing materials (e.g., graphite, PTFE), which may age, dry, or crack over prolonged use. Temperature fluctuations can also cause gland loosening, leading to leakage at the packing box.  Emergency Measures: · Tighten packing gland bolts to increase packing compression. · If ineffective, add or replace packing material. · Avoid over-tightening to prevent increased operating torque or stem damage. Prevention Recommendations: Regularly replace packing; select materials compatible with the media and operating temperature. For critical equipment, consider spring-loaded packing glands.   3. Casting Defects or Corrosion Perforation in Valve Body/Bonnet   Cause: Some low-quality valves have casting defects such as sand holes or shrinkage cavities. Prolonged exposure to corrosive media can cause localized perforation of the valve body, resulting in uncontrollable leakage. Emergency Measures: · For small leaks, temporary repairs using metal adhesives or cold welding are possible. · Large-scale damage requires immediate valve replacement. · For high-pressure or toxic/hazardous media, no pressurized repair is allowed; follow shutdown procedures strictly.  Prevention Recommendations: Purchase valves from reputable manufacturers; use corrosion-resistant materials (e.g., 304/316L stainless steel). Perform regular wall thickness inspections on critical pipelines.   Common Questions & Answers (Q&A)   Q1: Can all valve leaks be fixed by replacing packing?A: No. Packing replacement is effective only when leakage is due to packing aging or gland loosening. If the leakage stems from seal surface or valve body damage, other me...

Can Oil Pass Through a Strainer? How Pre-Filtration Works in Lubrication Systems
Can Oil Pass Through a Strainer? How Pre-Filtration Works in Lubrication Systems
2025-05-20

In any efficient and reliable lubrication system, oil cleanliness is a core factor affecting equipment lifespan and operational efficiency. Strainers, as the front-line filtration devices in lubrication systems, play a critical role in pre-filtration. However, engineers and operators often raise the following questions: Can oil pass through strainers smoothly? What exactly is the function of a strainer? How does it differ from subsequent fine filters?   This article systematically explains the role of strainers in lubrication systems, covering their working principles, pre-filtration objectives, and practical applications across different systems.   1. Can Oil Pass Through a Strainer?   Answer: Yes, but with limitations.   (1) Strainer Structure Allows Oil Flow A strainer is fundamentally a low-precision filter made of stainless steel mesh or perforated metal plates. It features uniform pores, typically sized between 80–500 μm (micrometers), allowing most clean oil to flow through unimpeded.   (2) Contaminants Are Blocked Particles such as metal shavings, seal fragments, and carbon deposits in the oil are intercepted by the strainer, preventing them from entering the oil pump or other critical components.   (3) Oil Temperature and Viscosity Affect Flow Efficiency Low temperatures or high-viscosity oil may reduce flow rates or even cause blockages. This is one reason for low oil pressure during system startup.   2. Objectives and Significance of Pre-Filtration   (1) Protecting the Oil Pump Internal pump components (gears, impellers, or plungers) are highly sensitive to solid particles. Pre-filtration prevents particles from entering the pump, avoiding premature wear or seizure.   (2) Reducing Load on Primary Filters By intercepting large contaminants, strainers allow primary filters (e.g., oil filter cartridges) to focus on finer impurities, extending their service life and maintaining stable system flow.   (3) Lowering System Failure Rates Pre-filtration reduces risks such as pump failure, orifice blockages, and lubrication breakdown caused by foreign particles, enhancing overall system reliability.   3. Typical Applications of Pre-Filtration Devices   Application System Strainer Installation Position Strainer Type Internal Combustion Engine Lubrication Oil sump → Pump inlet Coarse metal strainer Hydraulic Systems Tank outlet → Pump suction port Suction strainer or basket strainer Turbine Lubrication Systems Pump inlet Dual-chamber switchable suction strainer Transmission/Clutch Systems Oil sump → Circulation pump inlet Perforated plate + magnetic strainer   4. Design and Usage Considerations for Strainers   (1) Pore Size Selection Must Align with System Precision Requirements 80–100 μm: Typical for engine oil systems. 150–300 μm: Used in hydraulic equipment. >400 μm:  Suitable for low-pressure or open-loop systems.   (2...

Are Ball Valves Suitable for Water Systems? A Practical Guide for Engineers & Installers
Are Ball Valves Suitable for Water Systems? A Practical Guide for Engineers & Installers
2025-04-30

Ball valves, with their simple structure, easy operation, and excellent sealing performance, have become widely used control components in both industrial and residential sectors. Particularly in water supply systems, an increasing number of engineers and installers are choosing ball valves as the primary fluid control device. But are ball valves truly suitable for water systems? How should one properly select and install them to ensure long-term stable operation? This article provides a comprehensive overview from the perspectives of structural principles, performance characteristics, and application recommendations. 1. Advantages of Ball Valves in Water Systems (1) Quick Opening and Closing Ball valves can complete the opening and closing operation with a simple 90° rotation, making them easy to operate and highly responsive—ideal for emergency situations or water systems that require frequent switching.   (2) Excellent Sealing Performance High-quality ball valves are equipped with PTFE or reinforced sealing materials, enabling zero leakage. They are particularly suitable for water supply systems in residential buildings, commercial complexes, and industrial facilities where sealing performance is critical.   (3) Compact Structure and Space-Saving Compared to gate valves or globe valves, ball valves occupy less space and offer flexible installation, making them ideal for water modules with high equipment integration.   (4) Strong Corrosion Resistance Ball valves made of stainless steel, brass, or plastic materials (such as UPVC) offer excellent corrosion resistance, capable of handling various water qualities (soft water, hard water, reclaimed water) and different additives.   2. Application Scenarios Analysis Ball valves are suitable for the following types of water systems: (1) Domestic Water Systems: Such as internal building water supply, point-of-use control for sanitary fixtures, and garden irrigation systems. (2) Industrial Water Systems: Such as cooling water circulation systems, boiler feedwater systems, and water supply for cleaning equipment. (3) Water Treatment Systems: Including reverse osmosis pretreatment, greywater recycling, and wastewater transfer processes. (4) Special Applications: High-pressure hot water systems or cleaning water containing chemical additives.   However, caution should be exercised in the following scenarios: (1) High-Frequency Modulation Conditions Standard ball valves are not suitable for precise flow regulation. It is recommended to use V-port ball valves or control-type electric ball valves. (2) Water Containing Sand, Gravel, or High Levels of Suspended Solids A Y-strainer should be installed to prevent particle blockage or damage to the sealing surfaces. (3) High-Temperature Hot Water Systems High-temperature ball valves with metal sealing structures should be selected to prevent seal aging and deformation.   3. Key Selection Criteria To ensure stable operation o...

Pressure Seal Bonnet Gate Valve
加载中...

Pressure Seal Bonnet Gate Valve BW 8 Inch 2500LB

  • Payment:

    30% T/T When Order, 70% T/T Before Shipment
  • Product Origin:

    China
  • Color:

    Customization
  • Shipping Port:

    Shanghai China
  • Lead Time:

    35~60 days Ex Works After Order Confirmation
  • Material:

    Alloy Steel Gate Valve WC6
  • Method of Operation:

    Gear Operated Gate Valve
Inquiry now
Product Detail

The 8 inch Class 2500 gate valve is designed with pressure seal bonnet, butt weld connection, and gearbox operation. The 8 inch gate valve has carbon steel WCB body and trim 5.


Quick Detail

Type

Gate Valve

Size

8''

Design Pressure

ANSI 2500

Construction

Pressure Seal Bonnet, Flexible Wedge, Metal to Metal Seat

ConnectionType

Butt Weld (SW)

OperationType

Gearbox Operation

Body Material

A217 WC6

TrimMaterial

Trim 5

Design Code

API 600

Face to Face Dimension

ASME B16.10

End Connection

ASME B16.25

Pressure & Temp

ASME B16.34

Medium

Water, Oil and Gas

Origin

China


Dimension & Material

PSB Gate Valve With Butt Weld End

NPS      DN Class 2 2 1/2 3 4 6 8 10 12 14 16 18 20 24
50 65 80 100 150 200 250 300 350 400 450 500 600
L(RF) 900LB 368 419 381 457 610 737 838 965 1029 1130
1500LB 368 419 470 546 705 832 991 1130 1257 1384
2500LB 451 508 578 673 917 1022 1270
L1(BW) 900LB 216 254 305 355 508 660 787 914 991 1092 1346 1473 1600
1500LB 216 254 305 406 559 711 864 991 1067 1194 1697
2500LB 279 330 368 457 610 762 914 1041 1118 1245
L2(RTJ) 900LB 371 422 384 460 613 740 841 968 1038 1140
1500LB 371 422 473 549 711 841 1000 1146 1276 1407
2500LB 454 514 584 683 927 1038 1292
H(Opne) 900LB 554 637 680 796 1084 1372 1494 1550 1960 2210
1500LB 554 637 767 875 1094 1372 1655 1834 2150 2260 2460 2721 2940
2500LB 610 654 753 850 1254 1374 1685 1894 2226 2382 2585
W 900LB 300 350 350 400 560 460* 610* 610* 610* 760*
1500LB 300 450 450 560 305* 460* 610* 610* 760* 760*
2500LB 500 500 600 600 460* 460* 610*
Weight   (RF) 900LB 50 84 92 154 341 622 950 1295 1720 2380
1500LB 60 91 128 182 394 795 1370 2120 2800 3870
2500LB 121 175 195 229 720 1295 2250
Weight   (BW) 900LB 39 64 82 120 266 524 760 1090 1450 2018
1500LB 46 71 85 130 292 578 974 1615 2010 2815 3315 4150 5219
2500LB 88 135 144 158 500 892 1550 1978 2580 3780 5988
*Manual gear operator is recommended



No. Part WCB WC6 WC9  C5 CF8 CF8M
1 Body A216 WCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M
2 Seat A182 F6a A182 F22 A182 F22 A182 F5 A182 F304 A182 F316
3 Wedge A216 WCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M
4 Stem A182 F6a SAEHNV3 A182 F304 A182 F316
5 Stuffing Box A216 WCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M
6 Seal Ring ANSI 316L Flexible Graphite+316
7 Split Ring Steel F6 F6 F6 A182 F304 F316
8 Back Ring Steel Steel Steel Steel SS SS
9 Bolt A193 B7 A193 B7 A193 B7 A193 B7 A193 B8 A193 B8
10 Nut A194 2H A194 2H A194 2H A194 2H A194 Gr.8 A194 Gr.8
11 Yoke A216 WCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M
12 Bolt A193 B7 A193 B7 A193 B7 A193 B7 A193 B8 A193 B8
13 Nut A194 2H A194 2H A194 2H A194 2H A194 Gr.8 A194 Gr.8
14 Packing Plate ANSI 410 ANSI 410 ANSI 410 ANSI 410 ANSI 304 ANSI 316
15 Packing Flexible Graphite(Braided and Ring) or PTFE
16 Split Pin Steel Steel Steel Steel Steel Steel
17 Eyebolt A193 B7 A193 B7 A193 B7 A193 B7 A193 B8 A193 B8
18 Gland A182 F6 A182 F6 A182 F6 A182 F6 A182 F304 A182 F316
19 Gland Flange A105 A105 A105 A105 A182 F304 A182 F316
20 Nut A194 2H A194 2H A194 2H A194 2H A194 Gr.8 A194 Gr.8
21 Stud A193 B7 A193 B7 A193 B7 A193 B7 A193 B7 A193 B7
22 Stem Nut Ni-resist A439-D2
23 Gear Box Purchased
24 Protector Steel
25 Nameplate ANSI 304
26 Rivet ANSI 304


Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
Gate Valve
8" 1500LB Pressure Self Sealing Gate Valve WCC BW

8" 1500LB gate valve is made according to ASME B16.34 standard. The valve body is made of WCC. It has the structural characteristics of pressure self sealing, elastic gate and structural length of 711mm. The working principle of self sealing valve is mainly to use wedge sealing surface to seal under pressure.

Gate Valve
Pressure Seal Gate Valve 2 Inch 4500 LB SW API 602

The high-pressure Class 4500 gate valve is designed with PSB and SW end connection. Made of CS A105, the 2 inch gate valve follows the inspection standard API 598 and design standard API 602. Dervos could offer customizing service by providing clients with valves in different sizes, materials, standards, design pressure, structure, operation type and connection type.

Gate Valve
Pressure Seal Gate Valve 10'' 1500LB WCC BW PSB

10'' 1500LB gate valve is made according to ASME B16.34 standard. The valve body is made of WCC. It has the structural characteristics of pressure self sealing, rising stem, elastic wedge and structural length of 864mm. Both ends of the valve stem are threaded. It has BW connection type.

Globe Valve EN10213
PN25 DN80 Straight Type Globe Valve EN10213

EN 13709 Design and manufacture. EN558-1 Face to Face dimension. EN1092-B1 Flange and dimension. EN12266 Test and inspection standard.

DN100*65 PN16 Triple Eccentric Jacketed Metal Seated Butterfly Valve, Q235B, EN593, Turbine
DN100*65 PN16 Triple Eccentric Jacketed Metal Seated Butterfly Valve, Q235B, EN593, Turbine

DN100*65 PN16 triple eccentric jacketed metal seated butterfly valve is made according to EN 593 standard. The valve body is made of Q235B. It has the structural characteristics of insulation jacket, triple eccentric, two-way 1:1 pressure test. Its connection mode is EN1092-1 B1. And it has turbine operation mode.

Lever, DN15 PN320 Needle Valve, FNPT, Body SS316,
Lever, DN15 PN320 Needle Valve, FNPT, Body SS316, ASME B16.34

DN15 PN320 Needle valve is made according to ASME B16.34 standard. The valve body is made of SS316. It has the structural characteristics of one in, three out (1 1/2 "internal thread inlet. 2 1/2 "internal thread outlets, 1 M20 * 1.5 internal thread outlet). Its connection mode is FNPT. And it has lever operation mode.

DIN Single Plate WAFER Check Valve DN80 PN40
DIN Single Plate WAFER Check Valve DN80 PN40

The single-disc check valve, made of CF8, has excellent resistance to corrosion. Designed in accordance with API594, the valve is of a WAFER type.

DN50 PN40 Air Release Valve, RF Connection, Body WCB, AWWA M51
DN50 PN40 Air Release Valve, RF Connection, Body WCB, AWWA M51

DN50 PN40 air release valve is made according to AWWA M51 standard. The valve body is made of ASTM A216 WCB. It has the structural characteristics of composite GYFH-4.0. Its connection mode is RF.

DN200 PN25 Y Type Strainer, RF Connection, Body 1.0619, BS EN 13709
DN200 PN25 Y Type Strainer, RF Connection, Body 1.0619, BS EN 13709

DN200 PN25 Y Type Strainer is made according to BS EN 13709 standard. The valve body is made of EN 10213 1.0619. It has the structural characteristics of Y-shaped, mesh size: 1.6 mm, without drain plug. Its connection mode is RF.

Plug Valve
DN250 PN25 Sleeved Plug Valve RF WCB API599 Turbine Operation

DN250 PN25 plug valve is made according to API599 standard. The valve body is made of A216 WCB. It has the structural characteristics of soft sealing plug valve. Its connection mode is RF. And it has turbine operation mode.

RF, Body WCB, 10 600LB Trunnion Mounted Ball Valve, Turbine,
RF, Body WCB, 10" 600LB Trunnion Mounted Ball Valve, Turbine, API6D

10" 600LB Trunnion Mounted Ball valve is made according to API 6D standard. The valve body is made of ASTM A216 WCB. It has the structural characteristics of Full bore, fixed ball, fireproof, anti-static, anti-blowing valve stem. Its connection mode is RF. And it has Turbine operation mode.

Straight Pattern Globe Valve Flanged
Cast Steel Globe Valve 12 Inch ANSI 150 WCB Gearbox

The 12 inch 150 LB cast steel globe valve is made of carbon steel WCB body and trim 8, with gearbox, RF flange, BB, and plug disc. Quick Detail Type Globe Valve Size 12'' Pressure Class 150 Construction Bolted Bonnet, Straight Pattern,Plug Disc, OS&Y Connection Flanged Connection Operation GearOperated Design Code BS 1873 Face to Face ASME B16.10 Flange Connection ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material A216 WCB TrimMaterial Trim 8 Temperature Range -29℃~+427℃ Application WOG Origin China Dimension Class 150 NPS in 2 2 1/2 3 4 5 6 8 10 12 DN mm 50 65 80 100 125 150 200 250 300 L-L1 (RF-BW) in 8 8-1/2 9-1/2 11-1/2 14 16 19-1/2 24-1/2 27-1/2 mm 203 216 241 292 256 406 495 622 698 L2 (RTJ) in 8-1/2 9 10 12 14-1/2 16-1/2 20 25 28 mm 216 229 254 305 368 419 508 635 711 L3 mm 102 108 121 146 178 203 248 311 349 H (OPEN) in 14-11/16 15-3/8 16-9/16 20-1/4 21-3/16 22-5/15 24-5/8 28 39 mm 373 390 421 515 538 567 626 712 990 W in 7-7/8 9-7/8 9-7/8 11-13/16 11-13/16 13-3/4 15-3/4 17-3/4 24 mm 200 250 250 300 300 350 400 450 610 WT (kg) RF 22 29 42 64 77 105 154 288 507 BW 19 25 34 49 65 82 131 249 430 Related Knowledge What is the difference between a gate valve and a globe valve? Gate valves and globe valves are two of the most common valves we know. The differences beween them are: 1.Gate valve is used only for on-off function. But the globe valve could be used for shutting off and throttling at the same time.  2.The flow resistance of a globe valve is larger than a gate valve. Likewise, globe valves have more pressure drop than gate valves. 3.The gate valve require larger installation space than a globe valve from the perspective of opening height. 4.The gate valve sealing face suffers more abrasion than a globe valve. 5.The torque value of a globe valve is larger than a gate valve. Quality Checking Quality means everything in Dervos. Quality checking team will do inspections according to standard procedure and provide reports. Our QC team will check valve quality from casting and forging, machining, pressure testing, dimension checking, painting & packing.

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact