English

English

Get a Quote
Products

Hot Products

Company News

Line Blind Valve Interlocks and Position Verification: Preventing Unsafe Operation Under Pressure
Line Blind Valve Interlocks and Position Verification: Preventing Unsafe Operation Under Pressure
2026-09-18

A line blind valve creates positive isolation only after the solid plate is correctly positioned, fully restrained and capable of withstanding the process pressure. The dangerous part is the transition between the open and blinded states: many designs temporarily release the clamping force or expose part of the line while the plate moves. An interlock must therefore control an isolation sequence, not merely prevent the actuator from starting. A “closed” lamp, a limit-switch signal or a zero-pressure indication is useful evidence, but none of them independently proves that the line is safe to open.   Why Operating Sequence Matters More Than Actuator Type   Whether the line blind is manual, electric or hydraulic, it should not move until the process has been isolated, depressurized and drained. A powered actuator makes remote operation possible, but it also allows an incorrect command to be executed rapidly and from a location where the operator cannot see a release. A robust sequence normally requires: 1. Upstream and downstream block valves are closed and locked or otherwise secured. 2. The trapped section is vented or drained to a suitable disposal system. 3. Pressure has fallen below the project-defined permissive value. 4. A field operator or independent authorization confirms that the isolation arrangement is correct. 5. The line blind clamping mechanism is released. 6. The plate moves completely into the open or blind position. 7. The mechanism reclamps and mechanically secures the plate. 8. Final position and clamping status are recorded before process conditions are restored. This sequence matters because closing the adjacent valves does not remove trapped pressure. A blocked drain, leaking upstream valve, vaporizing liquid or thermal expansion can repressurize the cavity after an initial pressure reading.   AIG therefore recommends upstream isolation, bleed and pressure indication for line blind installations, with double block and bleed considered where a large hazardous inventory could be released. It also identifies pressure-sensing interlocks, controlled keys and secondary isolation verification as possible protection layers.   What Position Feedback Actually Proves   Position verification should answer three separate questions: · Is the solid or open plate in the intended location? · Is the plate fully clamped and mechanically retained? · Is the surrounding process condition safe for movement? These are different states and should not be represented by one shared switch. A limit switch normally confirms that the component driving the switch has reached a calibrated endpoint. It does not automatically prove that the blind plate followed the drive mechanism, that the plate is centred between the seats, or that the clamping load is adequate. A loose cam, bent bracket, damaged linkage or incorrectly adjusted switch can produce...

Blind Valve for Pipeline Maintenance: Positive Isolation Requirements Before Line Opening
Blind Valve for Pipeline Maintenance: Positive Isolation Requirements Before Line Opening
2026-09-10

Before a pipeline is opened, a blind valve should be treated as one part of an isolation system, not as a permit by itself. Its value is that it can place a visible physical barrier in the line, but that barrier only becomes meaningful when the site has also isolated, depressurized, drained, vented, locked, tagged, tested, and verified the correct section of piping.   Line opening is the moment when weak isolation becomes real. A closed valve may pass. A bleed point may be plugged. A drawing may be outdated. Liquid may remain trapped in a low point. Gas may migrate from an unexpected connection. This is why positive isolation for pipeline maintenance has to be judged as a chain of proof, not a single valve feature.   The Isolation Boundary Must Be Proven on the Drawing and in the Field   The first requirement is knowing exactly what is being isolated. Maintenance teams usually start from the P&ID or isolation plan, but the field verification is just as important. Tie-ins, bypasses, drains, vents, sample points, small-bore branches, equalizing lines, instrument connections, and thermal relief paths can all create energy routes around the expected isolation point.   A blind valve installed in the correct location can give strong physical isolation. Installed on the wrong side of a branch connection, it may protect the main line while leaving the work face exposed to pressure or hazardous material from a side path. That is not a valve failure; it is an isolation boundary failure.   Before line opening, the isolation plan should identify the upstream and downstream sources, the section to be opened, all possible re-pressurization routes, and the exact valve position required. The field check should confirm tag numbers, flow direction, blind position, locking status, and whether the valve can be seen and reached safely.   Positive Isolation Is More Than Seat Leakage   A blind valve differs from a normal shutoff valve because it uses a solid blind plate, spectacle plate, or sliding/swinging blind mechanism to block the bore. This reduces reliance on seat tightness alone. For maintenance work involving flange breaking, equipment opening, hot work, confined-space entry, or hazardous media, that physical barrier can be more defensible than a closed gate, globe, or ball valve.   Still, the phrase “positive isolation” should not be used loosely. The blind must be in the correct position, fully seated, mechanically restrained, locked or tagged according to the site procedure, and confirmed by position indication that maintenance personnel can understand. If the mechanism is stiff, partly engaged, poorly marked, or difficult to verify from the work area, the valve’s theoretical advantage becomes weaker.   The seal arrangement also matters. Some line blind valves rely on resilient seals, graphite seals, metal seating surfaces, or combined sealing designs depending on temperature, pressure, and ...

Line Blind Valve vs Double Block and Bleed: Choosing Positive Isolation for Refinery Shutdowns
Line Blind Valve vs Double Block and Bleed: Choosing Positive Isolation for Refinery Shutdowns
2026-09-04

In refinery shutdowns, the choice between a line blind valve and double block and bleed is not a contest between one safe method and one unsafe method. Both can be valid isolation methods, but they control risk in different ways.   A line blind valve creates isolation by moving a solid blind plate into the pipeline bore. The isolation is visible and mechanical. A double block and bleed arrangement isolates by closing two barriers and opening a bleed or vent between them, so trapped pressure or leakage can be released or monitored. The engineering question is not only “which one seals better?” It is “what work will happen after isolation, and how much reliance can the site accept on valve seats, bleed monitoring, and procedure control?”   Shutdown Work Changes the Isolation Standard   Routine instrument work, sampling maintenance, or short inspection tasks may justify a different isolation method from hot work, vessel entry, flange breaking, or long-duration turnaround maintenance. In a refinery, the same hydrocarbon line may be low-risk in one task and high-risk in another because the exposure changes. A DBB arrangement is useful when the work needs fast, verifiable valve isolation without moving a blind plate into the bore. The bleed point gives operators a way to confirm whether pressure is trapped between the isolation points or whether one of the seats may be passing. For many operating teams, that makes DBB practical for frequent or temporary isolation where breaking containment would add more work and more exposure. A line blind valve becomes stronger when the job needs visible physical separation from a live or potentially live system. If the isolated equipment will be opened, entered, welded, cleaned, or left out of service during a shutdown window, a solid blind plate reduces dependence on seat tightness. The valve still needs proper operation, locking, marking, and testing, but the core barrier is no longer only a seating surface.   Where DBB Earns Its Place   DBB is attractive because it can reduce downtime. A compact DBB valve or a two-valve DBB arrangement can isolate, bleed, and verify without removing a spool or installing a separate blind flange. For refinery units with many small-bore connections, drains, vents, sampling points, or instrument take-offs, that speed matters. The risk with DBB is that its safety case still depends on seat integrity, correct bleed routing, pressure monitoring, and disciplined lockout practice. If the bleed is not routed to a safe location, it may create a release hazard. If operators close two valves but do not prove the bleed, the system may only look isolated. If the valves have seat damage from coke, catalyst fines, thermal cycling, corrosion, or debris, the bleed point may reveal leakage rather than eliminate it. This is why DBB should be described clearly in the shutdown plan. Does the project mean two separate inline isolation valves with a drain...

Double Eccentric Butterfly Valve
加载中...

Double Offset Cast Iron Butterfly Valve EN593 PN10 DN500

  • Payment:

    30% T/T When Order, 70% T/T Before Shipment
  • Product Origin:

    China
  • Color:

    Customization
  • Shipping Port:

    Shanghai China
  • Lead Time:

    30~55 days Ex Works After Order Confirmation
  • Material:

    Ductile Iron Butterfly Valve
  • Method of Operation:

    Gear Operated
Inquiry now
Product Detail

The cast iron butterfly valve belongs to double offset type. also is soft seal butterfly valve,It owns a compact body, low torque value, and perfect sealing function, suited for water application with normal temperature range. 


Quick Detail

Type

Butterfly Valve

Nominal Size

DN500

Nominal Pressure

PN10

Structure

Double Offset, Soft Seated

Connection Type

Flange Type

Operation

Gear Operated

Design Code

EN 593

Face to Face

EN 558

End Connection

EN 1092

Test & Inspection

EN 12266

Body Material

Cast Iron GGG50

Temperature Range

-15℃~+150℃

Application

Water, Oil, Gas


Dimension Checking & Pressure Testing

EN593 Butterfly Valve


DN500 Butterfly Valve


Gear Operated Butterfly Valve


Tag & Packing

Butterfly Valve Manufacturer


Ductile Iron Butterfly Valve


Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
Metal Seated Lug SS Butterfly Valve Class 150
Triple Offset Butterfly Valve Metal Seated Lug 16 Inch

The 16 inch triple offset butterfly valve is designed with metal seat, stainless steel CF8M body, disc and stem. The fully lugged butterfly valve with gearbox has Class 150 design pressure as per API 609. Design Feature 1. Small volume, light weight, simple structure 2. Multi-layer metal seated/fully metal seated 3. Firesafe design 4. Anti-blowout stem 5. Small torque value for operating easily 6. Reliable sealing and could meet zero leakage requirement 7. With function of regulating flow  8. Triple eccentric design for minimized wear of sealing face Quick Detail Type Butterfly Valve Size 16'' Pressure ANS 150 Structure Triple Eccentric, Triple Offset, Metal Seated Connection Type Lug Type Operation Gearbox Operated Design Code API 609 Face to Face ASME B16.10 End Connection ASME B16.5 Test & Inspection API 598 Body Material A351 CF8M Temperature Range -29℃~+425℃ Application Water, Oil, Gas Material No Part Name Carbon steel to ASTM Alloy steel to ASTM Stainless steel to ASTM WCB WC6 WC9  C5 CF8 CF8M CF3 CF3M 1 Body A216 WCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 2 Below Axle Bush PTFE or Stainless Steel and Graphite Spiral Wound 3 Stem A182 F6 A182 F304 A182 F304 A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 4 Seat Ring F6 Stellite 6 Stellite 6 Stellite 6 A182 F304 A182 F316 A182 F304L A182 F316L 5 Butterfly Plate A216 WCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 6 Lock Ring A105 A182 F22 A182 F22 A182 F22 A182 F304 A182 F316 A182 F304L A182 F316L 7 Pin Carbon Steel or Alloy Steel 8 Screw Carbon Steel or Alloy Steel 9 Top Axle Bush PTFE or Stainless Steel and Graphite Spiral Wound 10 Packing Graphite+SS304 11 Bolt A193 B7 A193 B7 A193 B7 A193 B7 A193 B8 A193 B8 A193 B8 A193 B8 12 Nut A194 2H A194 2H A194 2H A194 2H A194 Gr.8 A194 Gr.8 A194 Gr.8 A194 Gr.8 13 Bolt A193 B7 A193 B7 A193 B7 A193 B7 A193 B8 A193 B8 A193 B8 A193 B8 14 Nut A194 2H A194 2H A194 2H A194 2H A194 Gr.8 A194 Gr.8 A194 Gr.8 A194 Gr.8 15 Yoke A216 WCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 16 Gland A182 F6 A182 F304 A182 F304 A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L

Triple Offset Butterfly Valve Manufacturers
Triple Eccentric Butterfly Valve 30 Inch 150LB WCB Flanged

The eccentric butterfly valve has triple offset design. It has excellent sealing performance and longer service life due to its small abrasion on sealing face during operation of valve. The 30'' butterfly valve is designed with ANSI 150 double flanged connection and fully metal seat. Quick Detail Type Butterfly Valve Size 30 Inch DesignPressure ANSI 150 Construction Triple Offset/ Triple Eccentric ConnectionType RF Double Flanged Type Operation Gearbox Operation Design Code API 609 Face to Face ASMEB16.10 End Connection ASMEB16.5 Test & Inspection API 598 Body Material A216 WCB TemperatureRange -29℃~+427℃ Application Water, Oil, Gas Available Product Range Norminal Size: 2 Inch ~150 Inch Design Pressure: 150LB~900LB Valve Connection: Flanged, Lug, Wafer, Butt Weld (BW) Valve Operation: :Lever/Wrench, Gearbox, Motorized, Pneumatic Body Material: Carbon Steel WCB, Stainless Steel CF8/CF8M/CF3/CF3M, Low Temperature Steel LCB/LCC Seat Material: Fully metal seat, SS+Graphite Seat

Triple Eccenctric Butterfly Valve
14in 150LB Triple Eccentric Wafer Butterfly Valve Gearbox Soft Seal

WCB 14inch 150LB Butterfly Valve Triple Eccentric Un-directional Seal Wafer Type Gear Handwheel Operation WCB Body WCB Disc F6a Stem PTFE Seal Ring 13Cr Overlay on Seat. Design and Manufacture API 609. Face to Face Dimension API 609. Flange and Dimension ASME B16.5. Test and Inspection API 598. Quick Detail Type Butterfly Valve Size 14” Pressure 150LB Construction Triple Eccentric Connection Wafer Operation Mode Gearbox Body Material A216 WCB Trim Material Ball/Stem F6a, Seat PTFE Design & Manufacture API 609 Pressure & Temp Code ASME B16.34 End to End ASME B16.10 End Connection ASME B16.5 Inspection API 598 Temperature Range -29℃~+200℃ Medium Oil, Water, Gas

 Triple Eccentric Butterfly Valve
Carbon Steel Triple Eccentric Butterfly Valve 150LB 20 Inch

The triple eccentric butterfly valve, made of carbon steel, is designed under Class 150 for a better performance of 0 leakage. With a gear operator, it can be better drove.   Quick Detail Type Butterfly Valve Nominal Size 20 Inch Nominal Pressure Class 150 Structure Triple Offset,Triple Eccentric, Metal Seated Connection Type Wafer Type Operation Gear Operated Design Code API 609 Face to Face ASME B16.10 End Connection ASME 16.5 Test & Inspection API 598 Body Material Carbon Steel Application Water, Oil, Gas   Founded in 2008, DERVOS VALVES INDUSTRY CO., LTD is a professional vendor, exporter and supplier of industrial valves, pipes and fittings. Dervos has expanded its business to five continents around the world, including Europe, Oceania, Africa, America and Asia.   Our commitment is to find the most suitable products for our clients in an efficient way. We adopt modern management skills to make sure efficiency in production and selling system.          

Triple Offset Butterfly Valve
30 Inch Triple Offset Butterfly Valve Metallic Seat Gearbox

You can found this valve in a various high performance applications such as steam, chilled water, gasoline, oil, jet fuels, natural gas, utility lines, process lines and in industries.

Double Offset Butterfly Valve
PN10 DN200 Double Offset Butterfly Valve Lug Type Stainless Steel

The PN10 DN200 double offset butterfly valve collects durable body and an easy replaceable seat for control services the power, chemical, petrochemical and other fields.

Butterfly Valve
API 609 Metal Seated Butterfly Valve CF8 12 Inch 150LB Gearbox

The 12 inch 150 LB triple eccentric butterfly valve is designed per API 609 with flange end and gearbox operation. The valve is made of stainless steel CF8 with metal seat design. Quick Detail Type Butterfly valve Size 12 Inch Pressure 150LB Construction Triple Offset/Eccentric, Metal Seat Connection Type Flange Operation Gearbox Design Code API 609 Face to Face ANSI B16.10 End Connection ANSI B16.5 Test & Inspection API 598 Body Material CF8 Applicable Temp -196℃~+800℃ Application Water, Oil, Gas Materials Dimension  

Butterfly Valve
10" 150LB Double Eccentric Butterfly Valve WCB API 609

10" 150LB butterfly valve is made according to API609 & ANSI B16.34 standard. The valve body is made of WCB + inconel. It has the structural characteristics of double eccentric, two-way pressure, reverse pressure 10bar. Its connection mode is lug type. And it has turbine operation mode.

Butterfly Valve
42" 150LBS Three Eccentric Butterfly Valve API609 CF8M

42" 150LBS butterfly valve is made according to API 609 standard. The valve body is made of CF8M. It has the structural characteristics of triple eccentric, multi-level and NACE. Its connection mode is RF flange. And it has turbine operation mode.

Butterfly Valve
26" 150LB High Performance Double Eccentric Butterfly Valve WCB API609

26" 150LB Butterfly valve is made according to API609 standard. The valve body is made of WCB. It has the structural characteristics of double eccentric, high-performance, bi-directional sealing, fireproof design and anti-corrosion turbine. Its connection mode is lug type. And it has turbine operation mode.

Butterfly Valve
API 14" 150LB High Performance Double Eccentric Butterfly Valve WCB

14" 150LB butterfly valve is made according to API 609 standard. The valve body is made of WCB. It has the structural characteristics of double eccentric and high performance. Its connection mode is lug type. And it has turbine with locking device operation mode.

Butterfly Valve
48" CL150 Three Eccentric Butterfly Valve CF8M API609 LUG

48" CL150 butterfly valve is made according to API 609 standard. The valve body is made of ASTM A351 CF8M. It has the structural characteristics of triple eccentricity. Its connection mode is lug to ASME B16.47B. And it has smooth rod with flange connection plate operation mode.

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact