English

English

Get a Quote
Products

Hot Products

Company News

Are Gate Valves Full Port?
Are Gate Valves Full Port?
2026-03-13

In industrial piping systems, gate valves are generally considered low-resistance isolation valves. When the valve is fully open, the gate is completely withdrawn from the flow path, allowing the fluid to pass through with minimal obstruction.   However, from a strict engineering perspective, not all gate valves are classified as full port valves.   If the seat bore is equal to or very close to the pipeline internal diameter, the flow experiences little or no restriction. In this case, the valve can be considered full port (or near full port). This design is commonly used in oil and gas pipelines, water transmission systems, and other applications where low pressure drop is required.   If the seat bore is slightly smaller than the pipe internal diameter, a minor flow restriction will occur inside the valve. In such cases, the valve is more accurately described as reduced bore. This configuration is more common in smaller sizes or cost-optimized valve designs.   In engineering practice, a simple selection logic can be applied: ● If the system requires minimum flow resistance or pipeline pigging, the valve bore must match the pipeline diameter. ● If the valve is used for general isolation purposes, most standard gate valves can already meet the required flow capacity.   Therefore, a concise conclusion can be drawn: Gate valves are typically close to full port designs, but whether they are truly full bore depends on whether the seat bore equals the pipeline internal diameter.   QA   Q1: Are gate valves always full bore?Not necessarily. If the seat bore equals the pipe internal diameter, the valve can be considered full bore. If it is slightly smaller, it is classified as reduced bore.   Q2: Why do gate valves have relatively low flow resistance?When the valve is fully open, the gate is completely removed from the flow path, allowing the fluid to pass through in a nearly straight line, which results in low pressure drop.   Q3: Are gate valves suitable for high-flow pipelines?Yes. If the system requires low pressure drop, gate valves are commonly used.   Q4: Is the concept of full port the same for gate valves and ball valves?Not exactly. For ball valves, the bore size is determined by the ball port diameter, while for gate valves, it is mainly determined by the seat bore diameter.

Installation of Large Diameter Ball Valves
Installation of Large Diameter Ball Valves
2026-03-09

Large diameter ball valves are commonly used in industries such as petroleum and chemical processing, power generation, long-distance pipeline transportation, and large-scale water treatment systems. If installation is not performed correctly, it may lead to sealing leakage, valve jamming, or structural stress damage. Therefore, proper installation practices are essential to ensure long-term stable operation.   1. Pre-installation Inspection   If pre-installation inspection is insufficient, operational failures are more likely to occur during service. First, inspect the valve body for transportation damage. If scratches, impact marks, or deformation are found on the valve body or sealing surfaces, installation should be stopped and the supplier should be contacted.   Next, verify valve model, pressure rating, and connection standards. If the system design pressure does not match the valve pressure class, operational safety risks may occur. For example, if a low-pressure class valve is mistakenly used in a high-pressure pipeline system, the valve body may experience plastic deformation under water hammer impact.   It is also necessary to check the condition of the ball surface and sealing rings. If there are scratches on the ball surface, sealing performance will be reduced. This is especially critical in gas transmission systems where micro-leakage is more likely.   2. Installation Direction   Large diameter ball valves usually have a flow direction marking. If the installation direction is incorrect, the following problems may occur: If the fluid flow direction matches the design direction, the operating torque will remain more stable. If the valve is installed in reverse, the stem may experience increased mechanical load, which will accelerate stem wear during long-term operation. For double-seal bidirectional ball valves, although bidirectional flow is allowed, installation according to the marked flow direction is still recommended to ensure more uniform sealing stress distribution. In high-temperature or steam systems, if the installation direction is incorrect, thermal expansion may accelerate sealing ring aging.   3. Pipeline Stress Control   Large diameter ball valves are heavy. If installed without proper support, additional bending moments may be transferred to flange connections. If pipeline systems experience axial displacement, pipeline supports should be installed for segmented fixation. If support structures are not provided, the valve body may bear long-term gravitational tensile load, eventually causing flange seal failure. It is generally recommended to install independent supports on both sides of large diameter ball valves. If the pipeline system is subject to thermal expansion and contraction, expansion compensation devices must be installed; otherwise, sealing surfaces may gradually fail.   4. Bolt Tightening Process   Flange connections of large diameter ball valves usually ...

Unite Strength, Create the Future Together --Dervos Annual Grand Event Successfully Concluded
Unite Strength, Create the Future Together --Dervos Annual Grand Event Successfully Concluded
2026-03-02

This year’s Dervos annual conference was noticeably more grand and well-organized than in previous years.   In the morning session, each department delivered its annual work summary, reviewing key projects and achievements over the past year. Teams also openly shared the challenges encountered during implementation and the practical experience gained along the way.   Through this cross-department exchange, everyone developed a clearer understanding of one another’s responsibilities and workflows, laying a stronger foundation for future collaboration and communication.     In the afternoon session, the Outstanding Employee awards were presented. Each nominee shared their work achievements and practical experience, demonstrating a strong sense of responsibility and execution across different roles. It is precisely this proactive mindset, collaborative spirit, and down-to-earth working approach of Dervos employees that drives the team steadily toward its shared goals.     Showing up on time every single day throughout the year — that’s quite an achievement. Ian has now received the Perfect Attendance Award for two consecutive years.     During the annual conference, Dervos also presented medals and exclusive commemorative gifts to employees who have completed five years of service.     Dervos values the long-term dedication and consistent commitment of its team members, and sincerely appreciates the trust and contributions they have made over the years. For many at Dervos, the company is not only a platform for professional growth, but also a stage where shared goals and collective efforts come to life. In the evening, the annual conference transitioned into the banquet segment. Performances and interactive games were seamlessly interspersed, creating a relaxed yet organized atmosphere.     Laughter and cheers echoed throughout the venue, and in the moment the camera shutter clicked, the excitement and joy were captured in a single frame.     Eric said: "Let’s dream together, DERVOS's dream. A dream where we all play a part, piece by piece, it becomes a reality." For Dervos, the annual meeting is not just about "summarizing the year," but about bringing our hearts together, strengthening our resolve in doing the same thing, and then continuing to move forward, step by step, with steady progress.            

Cryogenic Floating Ball Valve 4Inch 300LB RF Lever
加载中...

Cryogenic Floating Ball Valve 4Inch 300LB RF Lever

The 4 inch cryogenic ball valve, designed as per API609, has many parts equipped RPTFE --It has the lowest coefficient of friction and the best corrosion resistance of any known plastic material, so that the valve can handle quite extreme situations.

  • Payment:

    30% T/T When Order, 70% T/T Before Shipment
  • Product Origin:

    China
  • Color:

    Customization
  • Shipping Port:

    Shanghai, China
  • Lead Time:

    30~60 days Ex Works after order confirmation
  • Material:

    F316
  • Method of Operation:

    Lever
Inquiry now
Product Detail

Quick Details

Type

Ball Valve

Nominal Diameter

4"

NominalPressure

300LB

Construction

Bolted Weld, Extended Stem or Bonnet, Full Port

Connection

RF

Operation

Lever Operated

Body Material

F316

Design Code

API 607

Pressure & Temp

ASME B16.34

End toEnd Dimension

ASME B16.10

Connection Size of Flanges 

ASME B16.5

Inspection

API598

Temperature Range

-196℃~+120℃

Media

Oil, Water, Gas


Design Feature 

Extended stem and bonnet to position the stem packing above the cryogenic fluid and provide a column of warmer vapor that insulates the stem seal from the effects of low temperatures.

High-density seats and seals throughout the valve enable the valve to be rated down to -196°C service.


Vent hole is in the upstream face of the ball. This prevents the cold liquids from becoming trapped in the valve.

Stem primary seal and bearing are located near the packing end of the extended stem thus keeping these parts from the low temperatures and providing a blow-out proof stem design.

Valves are specially cleaned to remove all grease and oils that may react with the service media

Each valve after cleaning is packaged and sealed in a heavy poly bag to keep the valve clean until installation.


Technical Drawing


Our Service

Dervos customer service is one of our biggest competitive advantages. In Dervos, we provide-

 

1. Quotation within 24 hours or no later than 3 days

This will let you meet the quotation submission deadline and enhance your working efficiency

 

2. Weekly status report of your order

In this way, you will have a clear picture of your order. You do not need to waste time on pushing us for status update

 

3. An 18-month warranty period

A warranty certificate will issued after shipment and you will not have any concern after buying valves.

 

4. Solutions to complaints within 3 days

Quick and responsible actions to complaints will protect your reputation and reduce the financial loss as much as possible.




Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
LF2 Cryogenic Ball Valve
Extended Stem Cryogenic Ball Valve LF2 1500LB BW

The Class 1500 4'' cryogenic ball valve is designed with extended stem for low temperature application. The valve is made of LF2 with fully welded body, butt weld end and gearbox operation.    Design Feature-Fully welded & forged body-Extended stem or bonnet-Full port design and piggable-Anti blow-out stem-Antistatic function- Automatic cavity relief-Bi-directional seat and DBB design-With stem and seat grease fittings   Quick Detail Type Ball Valve Size 4" Pressure ANSI 1500 Construction One-Piece Body, Fully Weld, Extended Stem or Bonnet, Full Port Connection Butt Weld Operation Gearbox Operated Body Material Low Temperature Steel A350 LF2 Design Code API 6D Pressure & Temp ASME B16.34 End to End Dimension ASME B16.10 End Connection ASME B16.25 Inspection API 598 Temperature Range -46℃~+200℃ Media Oil, Water, Gas   Related KnowledgeWhat is the difference between full bore and reduced bore ball valve?The internal diameter of a full bore ball valve is the same as the inner diameter of the pipe. The full bore ball valve has little resistance and pressure drop to the flow. Plus, the full bore ball valve is piggable.However, the internal diameter of a reduced port (standard port) ball valve is smaller than the inner pipe size. Flow restriction caused by the reduced port will cause a pressure drop. And sometimes a pig to clean the pipe will get stuck in the reduced port ball valve.      

Steam Trap Valve
RF Connection, DN40 PN16 Ball Float Steam Trap Valve, Body CF8

DN40 PN16 ball float steam trap valve is made according to GB/T22654-2008 standard. The valve body is made of CF8. It has the structural characteristics of ball float type. Its connection mode is RF.

Gate Valve
Forged Steel Gate Valve 1 Inch 300LB Solid Wedge

The 1 inch forged steel gate valve is constructed of integral flange, bolted bonnet, rising stem and solid wedge and bolted bonnet. The valve has the design standard API 602 and inspection standard API 598. Dervos could offer customizing service by providing clients with valves in different sizes, materials, standards, design pressure, structure, operation type and connection type.

RTJ, 2 1500LB Dual Plate Wafer Type Check Valve, CF8M, API594
RTJ, 2" 1500LB Dual Plate Wafer Type Check Valve, CF8M, API594

2" 1500LB dual plate wafer type check valve is made according to API 594 standard. The valve body is made of A351 CF8M. It has the structural characteristics of double disc and wafer type. Its connection mode is RTJ.

3/8 800LB Y Type Strainer HC-276 NPT ASME B16.34
3/8" 800LB Y Type Strainer HC-276 NPT ASME B16.34

3/8" 800LB Y Type Strainer is made according to ASME B16.34 standard. The valve body is made of HC-276. It has the structural characteristics of Y-Type, Bolted Bonnet. Its connection mode is NPT. 

Slimline Monoflange
Body A105N, 2"x1/2" 600LB Slimline Monoflange, Hand Wheel, RF*FNPT Operation

2"x1/2" 600LB slimline monoflange is made according to ASME B16.34 standard. The valve body is made of A105N. It has the structural characteristics of BLOCK-BLEED-BLOCK and complies with NACE MR 0175. And The structural characteristics of the first and second isolation valves are: plug cover, open stem, needle valve, and handle operation. The structural characteristics of the exhaust valve are: plug cover, needle valve, with tamper proof design. The structural characteristics of the drain valve: 1/4 "NPT-F with hexagonal threaded plug (NPT-M, ASME B1.20.1; MoC: F316L,CL.6000#). Its connection mode is RF*FNPT. And it has hand wheel operation mode.

Cast Steel Globe Valve
8" 300LB Cast Steel Globe Valve RF WCB Gear BS1873

8" 300LB globe valve is made according to BS1873 standard. The valve body is made of ASTM A216 WCB+STL. It has the structural characteristics of straight through type and rising stem. Its connection mode is RF. And it has gear operation mode.

Angle Bellows Sealed Globe Valve
DN200 PN16 Angle Bellows Sealed Globe Valve RF 1.4408

DN200 PN16 angle bellows sealed globe valve is made according to BS EN 13709 standard. The valve body is made of EN 10213 1.4408. It has the structural characteristics of body cover bolt, exposed pole bracket, angle type, bellow seal. Its connection mode is RF. And it has hand wheel operation mode.

Gate Valve
Pressure Seal Gate Valve 2 Inch 4500 LB SW API 602

The high-pressure Class 4500 gate valve is designed with PSB and SW end connection. Made of CS A105, the 2 inch gate valve follows the inspection standard API 598 and design standard API 602. Dervos could offer customizing service by providing clients with valves in different sizes, materials, standards, design pressure, structure, operation type and connection type.

Ball Valve
DN100 PN25 3-Way Floating Ball Valve RF CF8M ISO17292

DN100 PN25 ball valve is made according to ISO 17292 standard. The valve body is made of A351-CF8M. It has the structural characteristics of T-shaped, floating ball, anti-fire, anti-static, anti-flying valve stem, bi-directional. Its connection mode is RF. And it has lever with dial operation mode.

Lift Check Valve
Forged Steel Flanged Lift Check Valve 1 Inch 150LB

The forged steel lift check valve is designed with class 150 pressure and 1 inch nominal size according to standard API 602. We also call it as piston check valve. Quick Detail Type Check Valve Size 1'' DesignPressure 150LB Construction Lift Type, Piston Type Connection RF Flange Design & Manufacture API 602 End to End ASME B16.10 Connection ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material ASTM A105N Trim Material Trim 5 Temp Range -29℃~+425℃ Media W.O.G. Dimension Checking Pressure Tesing Packing

Swing Check Valve
3" 150LB Swing Check Valve Body WCB RF API6D

3" 150LB Swing Check Valve is made according to API 6D standard. The valve body is made of A216 WCB. It has the structural characteristics of Bolted Bonnet, Swing Type. Its connection mode is RF. 

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact