English

English

Get a Quote
Products
  • Home
  • >
  • Strainer

  • >
  • 8" 150LB Cast Steel Y Type Strainer RF CF3M ASME B16.34

Hot Products

Company News

Line Blind Valve Interlocks and Position Verification: Preventing Unsafe Operation Under Pressure
Line Blind Valve Interlocks and Position Verification: Preventing Unsafe Operation Under Pressure
2026-09-18

A line blind valve creates positive isolation only after the solid plate is correctly positioned, fully restrained and capable of withstanding the process pressure. The dangerous part is the transition between the open and blinded states: many designs temporarily release the clamping force or expose part of the line while the plate moves. An interlock must therefore control an isolation sequence, not merely prevent the actuator from starting. A “closed” lamp, a limit-switch signal or a zero-pressure indication is useful evidence, but none of them independently proves that the line is safe to open.   Why Operating Sequence Matters More Than Actuator Type   Whether the line blind is manual, electric or hydraulic, it should not move until the process has been isolated, depressurized and drained. A powered actuator makes remote operation possible, but it also allows an incorrect command to be executed rapidly and from a location where the operator cannot see a release. A robust sequence normally requires: 1. Upstream and downstream block valves are closed and locked or otherwise secured. 2. The trapped section is vented or drained to a suitable disposal system. 3. Pressure has fallen below the project-defined permissive value. 4. A field operator or independent authorization confirms that the isolation arrangement is correct. 5. The line blind clamping mechanism is released. 6. The plate moves completely into the open or blind position. 7. The mechanism reclamps and mechanically secures the plate. 8. Final position and clamping status are recorded before process conditions are restored. This sequence matters because closing the adjacent valves does not remove trapped pressure. A blocked drain, leaking upstream valve, vaporizing liquid or thermal expansion can repressurize the cavity after an initial pressure reading.   AIG therefore recommends upstream isolation, bleed and pressure indication for line blind installations, with double block and bleed considered where a large hazardous inventory could be released. It also identifies pressure-sensing interlocks, controlled keys and secondary isolation verification as possible protection layers.   What Position Feedback Actually Proves   Position verification should answer three separate questions: · Is the solid or open plate in the intended location? · Is the plate fully clamped and mechanically retained? · Is the surrounding process condition safe for movement? These are different states and should not be represented by one shared switch. A limit switch normally confirms that the component driving the switch has reached a calibrated endpoint. It does not automatically prove that the blind plate followed the drive mechanism, that the plate is centred between the seats, or that the clamping load is adequate. A loose cam, bent bracket, damaged linkage or incorrectly adjusted switch can produce...

Blind Valve for Pipeline Maintenance: Positive Isolation Requirements Before Line Opening
Blind Valve for Pipeline Maintenance: Positive Isolation Requirements Before Line Opening
2026-09-10

Before a pipeline is opened, a blind valve should be treated as one part of an isolation system, not as a permit by itself. Its value is that it can place a visible physical barrier in the line, but that barrier only becomes meaningful when the site has also isolated, depressurized, drained, vented, locked, tagged, tested, and verified the correct section of piping.   Line opening is the moment when weak isolation becomes real. A closed valve may pass. A bleed point may be plugged. A drawing may be outdated. Liquid may remain trapped in a low point. Gas may migrate from an unexpected connection. This is why positive isolation for pipeline maintenance has to be judged as a chain of proof, not a single valve feature.   The Isolation Boundary Must Be Proven on the Drawing and in the Field   The first requirement is knowing exactly what is being isolated. Maintenance teams usually start from the P&ID or isolation plan, but the field verification is just as important. Tie-ins, bypasses, drains, vents, sample points, small-bore branches, equalizing lines, instrument connections, and thermal relief paths can all create energy routes around the expected isolation point.   A blind valve installed in the correct location can give strong physical isolation. Installed on the wrong side of a branch connection, it may protect the main line while leaving the work face exposed to pressure or hazardous material from a side path. That is not a valve failure; it is an isolation boundary failure.   Before line opening, the isolation plan should identify the upstream and downstream sources, the section to be opened, all possible re-pressurization routes, and the exact valve position required. The field check should confirm tag numbers, flow direction, blind position, locking status, and whether the valve can be seen and reached safely.   Positive Isolation Is More Than Seat Leakage   A blind valve differs from a normal shutoff valve because it uses a solid blind plate, spectacle plate, or sliding/swinging blind mechanism to block the bore. This reduces reliance on seat tightness alone. For maintenance work involving flange breaking, equipment opening, hot work, confined-space entry, or hazardous media, that physical barrier can be more defensible than a closed gate, globe, or ball valve.   Still, the phrase “positive isolation” should not be used loosely. The blind must be in the correct position, fully seated, mechanically restrained, locked or tagged according to the site procedure, and confirmed by position indication that maintenance personnel can understand. If the mechanism is stiff, partly engaged, poorly marked, or difficult to verify from the work area, the valve’s theoretical advantage becomes weaker.   The seal arrangement also matters. Some line blind valves rely on resilient seals, graphite seals, metal seating surfaces, or combined sealing designs depending on temperature, pressure, and ...

Line Blind Valve vs Double Block and Bleed: Choosing Positive Isolation for Refinery Shutdowns
Line Blind Valve vs Double Block and Bleed: Choosing Positive Isolation for Refinery Shutdowns
2026-09-04

In refinery shutdowns, the choice between a line blind valve and double block and bleed is not a contest between one safe method and one unsafe method. Both can be valid isolation methods, but they control risk in different ways.   A line blind valve creates isolation by moving a solid blind plate into the pipeline bore. The isolation is visible and mechanical. A double block and bleed arrangement isolates by closing two barriers and opening a bleed or vent between them, so trapped pressure or leakage can be released or monitored. The engineering question is not only “which one seals better?” It is “what work will happen after isolation, and how much reliance can the site accept on valve seats, bleed monitoring, and procedure control?”   Shutdown Work Changes the Isolation Standard   Routine instrument work, sampling maintenance, or short inspection tasks may justify a different isolation method from hot work, vessel entry, flange breaking, or long-duration turnaround maintenance. In a refinery, the same hydrocarbon line may be low-risk in one task and high-risk in another because the exposure changes. A DBB arrangement is useful when the work needs fast, verifiable valve isolation without moving a blind plate into the bore. The bleed point gives operators a way to confirm whether pressure is trapped between the isolation points or whether one of the seats may be passing. For many operating teams, that makes DBB practical for frequent or temporary isolation where breaking containment would add more work and more exposure. A line blind valve becomes stronger when the job needs visible physical separation from a live or potentially live system. If the isolated equipment will be opened, entered, welded, cleaned, or left out of service during a shutdown window, a solid blind plate reduces dependence on seat tightness. The valve still needs proper operation, locking, marking, and testing, but the core barrier is no longer only a seating surface.   Where DBB Earns Its Place   DBB is attractive because it can reduce downtime. A compact DBB valve or a two-valve DBB arrangement can isolate, bleed, and verify without removing a spool or installing a separate blind flange. For refinery units with many small-bore connections, drains, vents, sampling points, or instrument take-offs, that speed matters. The risk with DBB is that its safety case still depends on seat integrity, correct bleed routing, pressure monitoring, and disciplined lockout practice. If the bleed is not routed to a safe location, it may create a release hazard. If operators close two valves but do not prove the bleed, the system may only look isolated. If the valves have seat damage from coke, catalyst fines, thermal cycling, corrosion, or debris, the bleed point may reveal leakage rather than eliminate it. This is why DBB should be described clearly in the shutdown plan. Does the project mean two separate inline isolation valves with a drain...

Strainer
加载中...

8" 150LB Cast Steel Y Type Strainer RF CF3M ASME B16.34

8" 150LB strainer is made according to ASME B16.34 standard. The valve body is made of CF3M. It has the structural characteristics of Y type. Its connection mode is RF.

  • Payment:

    30% when order confirmed, 70% before shipment
  • Product Origin:

    China
  • Color:

    Customization
  • Shipping Port:

    Shanghai, China
  • Lead Time:

    30~60 days Ex Works after order confirmation
  • Material:

    A351 CF3M
Inquiry now
Product Detail

Product Description

Type

Y Type Strainer

Size

8"

Pressure

150LB

Connection

RF

Body Material

A351 CF3M

Design Norm

ASME B16.34

Face to Face Dimension

ASME B16.10

Flange Dimension

ASME B16.5

Test & Inspection Code

API 598

Temperature

-29 ~ 425°C

Applicable Medium

Water, Oil and Gas

Features

1. Fully automatic, maintenance-free, large filtering area, high filter efficiency;

2. Stainless steel material, filter precision optional, complete specifications, long service life.

Technical Drawing

Dimension Checking

Pressure Testing

Nameplate & Packing

Inspection report


Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
Socket Weld Y Strainer 1 Inch
Forged Y Type Strainer 1 Inch 1500LB SW

The 1 inch 1500LB y strainer is made of forged steel body and stainless steel 304 as the screen material. The high pressure y strainer with sw end is designed as per ASME B16.34. Design Feature 1.Forged Steel Body 2.Stainless Steel Screen 3.Customized Mesh for Screen 4.Installed Horizontally or Vertically 5.Ability to handle higher pressure Quick Detail Type Strainer Size 1'' DesignPressure 1500LB Construction Y Type Strainer, Bolted Bonnet ConnectionType SW ( Socket Weld) Design Code ASME B16.34 Face to Face ASME B16.10 End Connection ASME B16.11 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material ASME A105 ScreenMaterial SS304 TemperatureRange -29℃~+425℃ Application Water, Oil, Gas Related Knowledge What is the difference between Y strainer and basket strainer? Both y strainer and basket strainer take their name from their configurations. There are four differences between them. -First, y strainer can be installed either horizontally or vertically. But in most cases, basket strainer could only be in horizonal position. -Second, y strainer could handle higher pressure rating than basket type. -Third, for the ability to screen particulate, basket strainers are better than y strainers. -Lastly, basket strainer is easier to be cleaned than the y type strainer. In conlusion, Y-strainers are applicable for high-pressure pipelines with a low concentration of particles & solids and less cleaning needs. Vice versa for basket type strainer.

T Type Basket Strainer
Cast Steel Basket Type Strainer 1.5 Inch 150LB Flanged

The basket type strainer has 150LB design pressure and 1 1/2 inch size. The flanged strainer is made of LCC body and stainless steel screen. Quick Detail Type Strainer Size 1.5'' DesignPressure 150LB Construction Bolted Bonnet, Basket Type ConnectionType Flanged Design Code ASME B16.34 Face to Face ASME B16.10 End Connection ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material ASTM A352 LCC ScreenMaterial SS304 TemperatureRange -46℃~+345℃ Application Water, Oil, Gas Company Profile Founded in Xiamen in 2008, DERVOS VALVES INDUSTRY CO., LTD has accumulated rich experience in supplying and exporting industrial valves, from general types of gate valve, globe valve, check valve, ball valve, butterfly valve, plug valve, strainer to special valves like needle valve, control valve, relief valve, safety valve and steam trap. Dervos people are committed to provide our customers with best possible service and valve products at a competitive price. With over 500 valve suppliers, the rich resources we own enable us to find the most suitable products in a very short time for our customers. Purchasing System Dervos purchasing system plays an important role in order follow up and supplier management. What does our purchasing team do? -Confirm production plan with the factory -Follow up the order according to the production plan very closely -Take every measure to initiate all related resources to solve the delay crisis -Seek new suppliers and put them into our supplier pool by evaluating them on quality, equipment, certificates, price level, technical supports etc -Do annual evaluation on current suppliers and eliminate those unqualified ones. All these actions will make sure that clients’ order will be delivered on time and we can find most suitable products among qualified suppliers in an efficient way.

Stainless Steel CF8M Y Type Strainer
Stainless Steel CF8M Y Type Strainer 6 inch 8inch CL150

ASME B16.34 Y type Strainer Flat Flange Connection Bolt Cover ASTM A182 F316 ASTM A351 CF8M Gasket SS316 + Flexible Graphite Screens SS316 Drain Plug 3/4” NPT Bolt Bonnet B8M 8M 6 inch 150LB 8inch 150LB Design and manufacture ASME B16.34 Face to Face Dimension ASME B16.10 Flange Dimension ASME.B16.5 Test and Inspect API598 Quick Detail Type Y Type Strainer Size 6 inch 8 inch Pressure CL150 Construction Bolt Cover Connection FF Operation Mode / Body Material CF8M Cover F316 Design & Manufacture ASME B16.34 End to End ASME B16.10 End Connection ASME B16.5 Inspection API 6D, API 598 Temperature Range -29℃~+538℃ Medium Oil, Water, Gas

Strainer
DN250 PN40 DIN Y Type Strainer RF 1.0619 EN13709

DN250 PN40 Y-type strainer is made according to EN13709 standard. The valve body is made of EN 10213 1.0619. It has the structural characteristics of Y-type. It connection mode is RF.

Strainer
DN32 PN16 Cast Steel Y Type Strainer BC RF WCB

DN32 PN16 Y type strainer is made according to EN12516-1 standard. The valve body is made of WCB. It has the structural characteristics of pressure Y type. Its connection mode is RF.

Strainer
20" 125LB Strainer FF GGG50 SS304 API598

20" 125LB strainer is made according to manufacturer's standard. The valve body is made of GGG50. It has the structural characteristics of basket style and body cover bolted. Its connection mode is FF.

Strainer
Cast Steel 6" 150LB Basket Strainer Blue Filter RF WCB ASME B16.34

6" 150LB strainer is made according to ASME B16.34 standard. The valve body is made of ASTM A216 WCB. It has the structural characteristics of basket type. Its connection mode is RF.

Strainer
3" 1500LB Y Type Strainer WCB RTJ ASME B16.34 BC

3" 1500LB strainer is made according to ASME B16.34 standard. The valve body is made of ASTM A216 WCB. It has the structural characteristics of plug with DN20 blind flange. Its connection mode is RTJ.

Strainer
1" 2500LB Y Type Strainer BW F316H ASME B16.34

1" 2500LB strainer is made according to ASME B16.34 standard. The valve body is made of ASTM A182 F316H. It has the structural characteristics of pressure self sealing and Y type. Its connection mode is BW SCH160.

Strainer
API598 6" 150LB Y Type Strainer RF C95800 ASME B16.34

6" 150LB Y type strainer is made according to ASME B16.34 standard. The valve body is made of ASTM B148 C95800. It has the structural characteristics of bonnet with 1/2 "FNPT plug. Its connection mode is RF.

Strainer
6" 150LB Y Type Strainer RF LCB ASME B16.34

6" 150LB strainer is made according to ASME B16.34 standard. The valve body is made of ASTM A352 LCB. It has the structural characteristics of Y-shaped and bolt cover. Its connection mode is RF.

Strainer
6" 300LB Y Type Strainer RF WCB ASME B16.34

6" 300LB Y type strainer is made according to ASME B16.34 standard. The valve body is made of ASTM A216 WCB. It has the structural characteristics of Y-shaped and bolt cover. Its connection mode is RF.

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact