English

English

Get a Quote
Products
  • Home
  • >
  • Strainer

  • >
  • 6" 150LB Y Type Strainer RF LCB ASME B16.34

Hot Products

Company News

Can You Add a Line Blind Valve to an Existing Pipeline? Space, Fit and Installation Checks
Can You Add a Line Blind Valve to an Existing Pipeline? Space, Fit and Installation Checks
2026-09-24

Yes, a line blind valve can usually be added to an existing pipeline, but the job is rarely as simple as cutting out a short section and inserting the valve. The valve must fit the existing flanges and pressure class, but that is only the first check. It also needs room to release the sealing mechanism, move the blind plate, reclamp, and remain accessible for future operation. The modified pipework must then be supported, inspected and tested before it returns to service. A valve that fits between the pipe ends but cannot complete its operating stroke is not a workable retrofit.   Start With the Full Operating Envelope   Face-to-face length tells you how much pipe must be removed. It does not tell you how much space the valve needs once it starts moving. A swing-type line blind needs a clear arc for the spectacle plate. That space may extend well beyond the valve body. Nearby pipework, cable trays, handrails, platforms, insulation and structural steel can all block the movement. A sliding design needs enough space for the plate to travel sideways or vertically. The drive mechanism, gearbox, hydraulic cylinder or actuator adds another clearance requirement. Check the manufacturer’s general arrangement drawing for: ● Face-to-face length ● Maximum body width and height ● Full plate travel or swing radius ● Handwheel, gearbox or actuator clearance ● Space needed to remove seals and internal parts ● Lifting points and rigging access ● Safe standing position for the operator   Do not measure only from the valve centerline. A gear operator may clear the adjacent pipe while the blind plate still strikes it halfway through the stroke. Orientation matters too. On vertical piping, some designs require a specific mechanism position so gravity cannot pull an unclamped component out of place. Manufacturer instructions for one cam-operated design, for example, call for the cam mechanism to be installed below the spectacle plate on a vertical line.    Check the Existing Pipeline Before Choosing the Valve   Old drawings are useful, but the final fit should be based on field measurements. Existing pipelines may have been repaired, rerouted or pulled out of alignment since the original drawings were issued. Record the actual: ● Pipe outside diameter and schedule ● Flange standard, size, class and facing ● Distance between flange faces or proposed cut points ● Pipe centerline and flange orientation ● Available movement in the existing line ● Insulation and heat-tracing thickness ● Nearby supports, guides and expansion joints ● Operating and design pressure and temperature ● Medium, corrosion allowance and material specification   Flanges that appear similar may use different drilling, facing or dimensions. Confirm the complete flange designation rather than relying on nominal size and pressure class alone. The selected gasket must also suit the flange facing, medium, temperature and surface finish. Installing a new valve betw...

Line Blind Valve Interlocks and Position Verification: Preventing Unsafe Operation Under Pressure
Line Blind Valve Interlocks and Position Verification: Preventing Unsafe Operation Under Pressure
2026-09-18

A line blind valve creates positive isolation only after the solid plate is correctly positioned, fully restrained and capable of withstanding the process pressure. The dangerous part is the transition between the open and blinded states: many designs temporarily release the clamping force or expose part of the line while the plate moves. An interlock must therefore control an isolation sequence, not merely prevent the actuator from starting. A “closed” lamp, a limit-switch signal or a zero-pressure indication is useful evidence, but none of them independently proves that the line is safe to open.   Why Operating Sequence Matters More Than Actuator Type   Whether the line blind is manual, electric or hydraulic, it should not move until the process has been isolated, depressurized and drained. A powered actuator makes remote operation possible, but it also allows an incorrect command to be executed rapidly and from a location where the operator cannot see a release. A robust sequence normally requires: 1. Upstream and downstream block valves are closed and locked or otherwise secured. 2. The trapped section is vented or drained to a suitable disposal system. 3. Pressure has fallen below the project-defined permissive value. 4. A field operator or independent authorization confirms that the isolation arrangement is correct. 5. The line blind clamping mechanism is released. 6. The plate moves completely into the open or blind position. 7. The mechanism reclamps and mechanically secures the plate. 8. Final position and clamping status are recorded before process conditions are restored. This sequence matters because closing the adjacent valves does not remove trapped pressure. A blocked drain, leaking upstream valve, vaporizing liquid or thermal expansion can repressurize the cavity after an initial pressure reading.   AIG therefore recommends upstream isolation, bleed and pressure indication for line blind installations, with double block and bleed considered where a large hazardous inventory could be released. It also identifies pressure-sensing interlocks, controlled keys and secondary isolation verification as possible protection layers.   What Position Feedback Actually Proves   Position verification should answer three separate questions: · Is the solid or open plate in the intended location? · Is the plate fully clamped and mechanically retained? · Is the surrounding process condition safe for movement? These are different states and should not be represented by one shared switch. A limit switch normally confirms that the component driving the switch has reached a calibrated endpoint. It does not automatically prove that the blind plate followed the drive mechanism, that the plate is centred between the seats, or that the clamping load is adequate. A loose cam, bent bracket, damaged linkage or incorrectly adjusted switch can produce...

Blind Valve for Pipeline Maintenance: Positive Isolation Requirements Before Line Opening
Blind Valve for Pipeline Maintenance: Positive Isolation Requirements Before Line Opening
2026-09-10

Before a pipeline is opened, a blind valve should be treated as one part of an isolation system, not as a permit by itself. Its value is that it can place a visible physical barrier in the line, but that barrier only becomes meaningful when the site has also isolated, depressurized, drained, vented, locked, tagged, tested, and verified the correct section of piping.   Line opening is the moment when weak isolation becomes real. A closed valve may pass. A bleed point may be plugged. A drawing may be outdated. Liquid may remain trapped in a low point. Gas may migrate from an unexpected connection. This is why positive isolation for pipeline maintenance has to be judged as a chain of proof, not a single valve feature.   The Isolation Boundary Must Be Proven on the Drawing and in the Field   The first requirement is knowing exactly what is being isolated. Maintenance teams usually start from the P&ID or isolation plan, but the field verification is just as important. Tie-ins, bypasses, drains, vents, sample points, small-bore branches, equalizing lines, instrument connections, and thermal relief paths can all create energy routes around the expected isolation point.   A blind valve installed in the correct location can give strong physical isolation. Installed on the wrong side of a branch connection, it may protect the main line while leaving the work face exposed to pressure or hazardous material from a side path. That is not a valve failure; it is an isolation boundary failure.   Before line opening, the isolation plan should identify the upstream and downstream sources, the section to be opened, all possible re-pressurization routes, and the exact valve position required. The field check should confirm tag numbers, flow direction, blind position, locking status, and whether the valve can be seen and reached safely.   Positive Isolation Is More Than Seat Leakage   A blind valve differs from a normal shutoff valve because it uses a solid blind plate, spectacle plate, or sliding/swinging blind mechanism to block the bore. This reduces reliance on seat tightness alone. For maintenance work involving flange breaking, equipment opening, hot work, confined-space entry, or hazardous media, that physical barrier can be more defensible than a closed gate, globe, or ball valve.   Still, the phrase “positive isolation” should not be used loosely. The blind must be in the correct position, fully seated, mechanically restrained, locked or tagged according to the site procedure, and confirmed by position indication that maintenance personnel can understand. If the mechanism is stiff, partly engaged, poorly marked, or difficult to verify from the work area, the valve’s theoretical advantage becomes weaker.   The seal arrangement also matters. Some line blind valves rely on resilient seals, graphite seals, metal seating surfaces, or combined sealing designs depending on temperature, pressure, and ...

Strainer
加载中...

6" 150LB Y Type Strainer RF LCB ASME B16.34

6" 150LB strainer is made according to ASME B16.34 standard. The valve body is made of ASTM A352 LCB. It has the structural characteristics of Y-shaped and bolt cover. Its connection mode is RF.

  • Payment:

    30% when order confirmed, 70% before shipment
  • Product Origin:

    China
  • Color:

    Customization
  • Shipping Port:

    Shanghai, China
  • Lead Time:

    30~60 days Ex Works after order confirmation
  • Material:

    ASTM A352 LCB
Inquiry now
Product Detail

Product Description

Type

Y Type Strainer

Size

6"

Pressure

150LB

Connection

RF

Body Material

ASTM A352 LCB

Design Norm

ASME B16.34

Face to Face Dimension

ASME B16.10

Flange Dimension

ASME B16.5

Test & Inspection Code

API 598

Temperature

-46 ~ 345°C

Applicable Medium

Water, Oil and Gas

Features

1. Advanced structure, low resistance, and convenient sewage discharge;

2. Easy to clean, can be installed separately.

Technical Drawing

Dimension Checking

Pressure Testing

Painting

Nameplate & Packing

Inspection report

Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
Socket Weld Y Strainer 1 Inch
Forged Y Type Strainer 1 Inch 1500LB SW

The 1 inch 1500LB y strainer is made of forged steel body and stainless steel 304 as the screen material. The high pressure y strainer with sw end is designed as per ASME B16.34. Design Feature 1.Forged Steel Body 2.Stainless Steel Screen 3.Customized Mesh for Screen 4.Installed Horizontally or Vertically 5.Ability to handle higher pressure Quick Detail Type Strainer Size 1'' DesignPressure 1500LB Construction Y Type Strainer, Bolted Bonnet ConnectionType SW ( Socket Weld) Design Code ASME B16.34 Face to Face ASME B16.10 End Connection ASME B16.11 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material ASME A105 ScreenMaterial SS304 TemperatureRange -29℃~+425℃ Application Water, Oil, Gas Related Knowledge What is the difference between Y strainer and basket strainer? Both y strainer and basket strainer take their name from their configurations. There are four differences between them. -First, y strainer can be installed either horizontally or vertically. But in most cases, basket strainer could only be in horizonal position. -Second, y strainer could handle higher pressure rating than basket type. -Third, for the ability to screen particulate, basket strainers are better than y strainers. -Lastly, basket strainer is easier to be cleaned than the y type strainer. In conlusion, Y-strainers are applicable for high-pressure pipelines with a low concentration of particles & solids and less cleaning needs. Vice versa for basket type strainer.

T Type Basket Strainer
Cast Steel Basket Type Strainer 1.5 Inch 150LB Flanged

The basket type strainer has 150LB design pressure and 1 1/2 inch size. The flanged strainer is made of LCC body and stainless steel screen. Quick Detail Type Strainer Size 1.5'' DesignPressure 150LB Construction Bolted Bonnet, Basket Type ConnectionType Flanged Design Code ASME B16.34 Face to Face ASME B16.10 End Connection ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material ASTM A352 LCC ScreenMaterial SS304 TemperatureRange -46℃~+345℃ Application Water, Oil, Gas Company Profile Founded in Xiamen in 2008, DERVOS VALVES INDUSTRY CO., LTD has accumulated rich experience in supplying and exporting industrial valves, from general types of gate valve, globe valve, check valve, ball valve, butterfly valve, plug valve, strainer to special valves like needle valve, control valve, relief valve, safety valve and steam trap. Dervos people are committed to provide our customers with best possible service and valve products at a competitive price. With over 500 valve suppliers, the rich resources we own enable us to find the most suitable products in a very short time for our customers. Purchasing System Dervos purchasing system plays an important role in order follow up and supplier management. What does our purchasing team do? -Confirm production plan with the factory -Follow up the order according to the production plan very closely -Take every measure to initiate all related resources to solve the delay crisis -Seek new suppliers and put them into our supplier pool by evaluating them on quality, equipment, certificates, price level, technical supports etc -Do annual evaluation on current suppliers and eliminate those unqualified ones. All these actions will make sure that clients’ order will be delivered on time and we can find most suitable products among qualified suppliers in an efficient way.

Stainless Steel CF8M Y Type Strainer
Stainless Steel CF8M Y Type Strainer 6 inch 8inch CL150

ASME B16.34 Y type Strainer Flat Flange Connection Bolt Cover ASTM A182 F316 ASTM A351 CF8M Gasket SS316 + Flexible Graphite Screens SS316 Drain Plug 3/4” NPT Bolt Bonnet B8M 8M 6 inch 150LB 8inch 150LB Design and manufacture ASME B16.34 Face to Face Dimension ASME B16.10 Flange Dimension ASME.B16.5 Test and Inspect API598 Quick Detail Type Y Type Strainer Size 6 inch 8 inch Pressure CL150 Construction Bolt Cover Connection FF Operation Mode / Body Material CF8M Cover F316 Design & Manufacture ASME B16.34 End to End ASME B16.10 End Connection ASME B16.5 Inspection API 6D, API 598 Temperature Range -29℃~+538℃ Medium Oil, Water, Gas

Strainer
DN250 PN40 DIN Y Type Strainer RF 1.0619 EN13709

DN250 PN40 Y-type strainer is made according to EN13709 standard. The valve body is made of EN 10213 1.0619. It has the structural characteristics of Y-type. It connection mode is RF.

Strainer
8" 150LB Cast Steel Y Type Strainer RF CF3M ASME B16.34

8" 150LB strainer is made according to ASME B16.34 standard. The valve body is made of CF3M. It has the structural characteristics of Y type. Its connection mode is RF.

Strainer
DN32 PN16 Cast Steel Y Type Strainer BC RF WCB

DN32 PN16 Y type strainer is made according to EN12516-1 standard. The valve body is made of WCB. It has the structural characteristics of pressure Y type. Its connection mode is RF.

Strainer
20" 125LB Strainer FF GGG50 SS304 API598

20" 125LB strainer is made according to manufacturer's standard. The valve body is made of GGG50. It has the structural characteristics of basket style and body cover bolted. Its connection mode is FF.

Strainer
Cast Steel 6" 150LB Basket Strainer Blue Filter RF WCB ASME B16.34

6" 150LB strainer is made according to ASME B16.34 standard. The valve body is made of ASTM A216 WCB. It has the structural characteristics of basket type. Its connection mode is RF.

Strainer
3" 1500LB Y Type Strainer WCB RTJ ASME B16.34 BC

3" 1500LB strainer is made according to ASME B16.34 standard. The valve body is made of ASTM A216 WCB. It has the structural characteristics of plug with DN20 blind flange. Its connection mode is RTJ.

Strainer
1" 2500LB Y Type Strainer BW F316H ASME B16.34

1" 2500LB strainer is made according to ASME B16.34 standard. The valve body is made of ASTM A182 F316H. It has the structural characteristics of pressure self sealing and Y type. Its connection mode is BW SCH160.

Strainer
API598 6" 150LB Y Type Strainer RF C95800 ASME B16.34

6" 150LB Y type strainer is made according to ASME B16.34 standard. The valve body is made of ASTM B148 C95800. It has the structural characteristics of bonnet with 1/2 "FNPT plug. Its connection mode is RF.

Strainer
6" 300LB Y Type Strainer RF WCB ASME B16.34

6" 300LB Y type strainer is made according to ASME B16.34 standard. The valve body is made of ASTM A216 WCB. It has the structural characteristics of Y-shaped and bolt cover. Its connection mode is RF.

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact