English

English

Get a Quote
Products

Hot Products

Company News

Will a Line Blind Spill Product During Changeover? Open vs Non-Spill vs Enclosed Designs
Will a Line Blind Spill Product During Changeover? Open vs Non-Spill vs Enclosed Designs
2026-10-16

Yes, an open-body line blind can release residual product when it changes between the open and blind positions. A non-spill design does not make that residue disappear; it catches the liquid in a partial enclosure and directs it to a drain. An enclosed design can provide better control of liquid and vapour, but only when its housing, drain, vent and purge connections are engineered for the service. None of these labels should be read as permission to move the blind under live line pressure.   Why Product Can Escape During Changeover   When a line blind is fully clamped, its seals contain the process and the solid plate provides positive isolation in the blind position. Changeover is different. The sealing faces must separate before the spectacle or sliding plate can move. During that interval, the body cavity and plate path may be open to the surrounding area.   The line should already be isolated, depressurised and drained, but “drained” rarely means perfectly dry. Liquid can remain as a film on the plate, collect in the lower body, or sit in a poorly drained pipe pocket. Gas service may leave flammable, toxic or odorous vapour. The amount released therefore depends as much on piping layout and the shutdown procedure as on the line blind itself.   The Three Designs Manage Residue Differently   Open-body design   Residual liquid can drip from the exposed plate path into a temporary tray or the work area, while vapour disperses locally. This arrangement can suit water, steam condensate or other manageable media where easy access and visual inspection matter. It presents the highest potential for floor contamination and operator exposure.   Non-spill design   A bottom-and-side cover catches drips and sends them to a drain or recovery container; the top may remain open. This design is commonly considered for fuel terminals, marine service and liquid duties where ground or deck contamination must be controlled. It reduces dripping but may not contain vapour, and a blocked drain defeats its purpose.   Enclosed design   A housing surrounds more or all of the plate travel and may connect to a closed drain, purge, vent, flare or vapour-recovery system. It is better suited to toxic, flammable, odorous or environmentally sensitive service requiring controlled containment. The tradeoff is greater complexity in purging, inspection and maintenance, together with the need to manage trapped pressure deliberately.   These names are not perfectly standardised across manufacturers. One supplier's “non-spill” model may be open at the top, while another product described as enclosed may use a more complete casing. The RFQ should show the enclosure arrangement and identify every opening rather than relying on the product name.   Non-Spill Does Not Automatically Mean Zero Release   For a liquid with low volatility, catching the remaining drops and routing them into a closed contai...

How Often Do You Open the Pipeline? When Is a Line Blind Valve Worth Installing?
How Often Do You Open the Pipeline? When Is a Line Blind Valve Worth Installing?
2026-09-30

A line blind valve is worth evaluating when a pipeline is blinded several times a year, or when one conventional changeover causes hours of shutdown, lifting work or significant exposure to hazardous residue. No universal cycle count guarantees payback. A large critical line operated twice a year may justify the investment, while a small accessible line operated monthly may not.   The decision should be based on the cost and risk of each complete isolation event, not frequency alone.   There Is No Standard “Two Operations per Year” Rule   Some suppliers use one or two annual changeovers as a screening threshold. That can start a discussion, but it is not an engineering rule. Frequency has very different consequences on a DN50 utility line and a DN600 process-gas main.   For a preliminary review, the following bands are useful but not mandatory: Blinding frequency  Initial interpretation Once per major turnaround or less A removable blind or spectacle blind is often more economical. One to three times per year Compare labor, lifting, outage duration and medium risk carefully. Quarterly to monthly A quick-action line blind is normally a strong candidate. Weekly or more often Purpose-built or automated isolation deserves detailed review; also confirm that a line blind is suitable for the required cycle duty.   A low operating frequency can still support installation when every event requires scaffolding, a crane, several pipefitters or a long production interruption. Conversely, frequent operation does not justify a line blind if the process cannot accommodate its pressure, temperature, materials or maintenance needs.   Count the Complete Changeover   Traditional blinding is more than moving a plate. After the line is made safe, workers loosen bolting, spread the flange joint, handle the blind or spacer, replace gaskets, restore alignment, tighten the joint and complete leak checks. Large sizes add rigging and access equipment.   A quick-action line blind keeps the spectacle or sliding plate supported inside the installed assembly. Manufacturer literature commonly reports one-person changeover in minutes rather than the man-hours needed for conventional flange work. Those figures are useful for screening, but the project calculation should use the plant’s own procedures and recorded shutdown times.   Use a simple comparison: Annual avoided cost = operations per year x cost avoided per operation   Avoided cost may include pipefitter hours, rigging, scaffolding, gaskets and bolting, leak testing and the production value of saved time. Keep categories separate to avoid double counting. Compare the annual saving with the line blind’s additional installed price and maintenance cost.   Risk Can Matter More Than Simple Payback   Repeated flange separation creates opportunities for residual-medium exposure, damaged flange faces, poor alignment and inconsistent bolt load...

Blind Valve vs Blind Flange: Which Is Better When a Pipeline Needs to Be Opened Often?
Blind Valve vs Blind Flange: Which Is Better When a Pipeline Needs to Be Opened Often?
2026-09-30

When a pipeline must be opened and positively isolated often, a line blind valve is usually the better choice. It keeps the blind mechanism permanently installed and lets operators change between open and blocked positions without repeatedly removing a bolted end closure. A blind flange costs less and has fewer moving parts, but it is better suited to closing a pipe end that will remain closed for long periods.   This answer assumes that “blind flange” means a solid flange bolted to the end of a pipe or nozzle. A spectacle blind or a removable spade installed between two flanges is a different device, although it creates a similar solid-metal isolation barrier.   Frequent Opening Changes the Cost Calculation   The purchase price favors the blind flange. Its construction is simple, and maintenance is largely limited to checking the flange face, gasket, studs and nuts. If the closure will be disturbed only during an occasional turnaround, that simplicity is difficult to beat.   Repeated opening changes the picture. Removing a blind flange requires the line to be shut down, depressurized, drained or purged, and verified safe. The bolts must then be loosened, the flange supported and the sealing faces separated. Larger flanges may require lifting equipment. Reassembly introduces a new gasket, controlled bolt tightening and a leak test. None of these steps is unusual, but repeating them turns a low-cost component into a labor-intensive operating method.   A line blind valve also requires the line to be isolated and depressurized before changing position unless its approved design and operating procedure explicitly state otherwise. Its advantage is mechanical handling: the plate, spacer or sliding element remains captured in the body, and the mechanism separates, moves and reclamps the sealing faces. Manual gearing may suit moderate operating forces; electric, pneumatic or hydraulic actuation may be justified for large sizes or remote operation.   The Blind Valve Reduces Handling but Adds Equipment to Maintain   For frequent switching, a blind valve can shorten the task and reduce repeated handling of heavy plates, bolts and gaskets. Its open or closed position is normally visible from the external plate or position indication, which helps field verification. It also avoids repeatedly forcing connected piping apart to insert or remove a blind.   Those benefits come with additional maintenance. Guides, screws, gearboxes, hydraulic components, seals and interlocks must remain functional. Product deposits or corrosion can obstruct plate travel, while damaged sealing surfaces can prevent reliable reclamping. The installation therefore needs drainage, cleaning access and enough surrounding clearance to complete the full movement and service the mechanism.   A blind flange has no operating mechanism to seize. However, frequent removal can damage flange faces, stretch or corrode bolting, disturb pipe al...

Swing Type Check Valve 2 300LB WCB RF
加载中...

Swing Type Check Valve 2" 300LB WCB RF

  • Payment:

    30% when order confirmed, 70% before shipment
  • Product Origin:

    china
  • Color:

    Customization
  • Shipping Port:

    Shanghai, China
  • Lead Time:

    30~60 days Ex Works after order confirmation
  • Material:

    A216 WCB
Inquiry now
Product Detail

2" 300LB Swing Check Valve is made according to BS 1868 standard. The valve body is made of WCB. It has the structural characteristics of Bolted Cover, Swing Type. Its connection mode is RF.

 

Product Parameters

 

Type

Swing Check Valve

Size

2"

Pressure

300LB

Connection

RF

Body Material

A216 WCB

Design Norm

BS 1868

Face to Face

ASME B16.10

Flange dimension

ASME B16.5

Test & Inspection Code

API 598

Temperature

-29 ~ 425°C

Applicable Medium

Water, Oil and Gas

 

Features

1. Swing Check Design: Provides automatic non-return protection to prevent reverse flow and protect downstream equipment.  

2.WCB Body with 300LB RF Ends: Cast steel construction and raised-face flanged connections provide reliable performance for demanding industrial pipeline service.

 

Technical Drawing

Swing Check Valve

Dimension Checking

Swing Check Valve

Pressure Testing

Swing Check Valve

Painting

Swing Check Valve

Spectrum

Swing Check Valve

Nameplate & Packing

Swing Check Valve

Inspection Report

Swing Check Valve Suppliers

Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
BS 1868 Swing Type Check Valve
8 Inch Swing Check Valve 1500 LB WCB Flanged BB BS 1868

The 8 inch non return check valve conforms to BS 1868 design code, with bolted bonnet and swing type disc. The flanged check valve is made of carbon steel A216 WCB. Design Feature 1.BB: bolted bonnet 2.Swing type disc 3.Reduced bore design 4.Superior flow rates 5.Minimized friction loss 6.Standard trim material for selection 7.External or internal hinge pin available on request 8.Cylinder and counter weight available on request 9.Bare stem and actuators are available on request Quick Detail Type Check Valve Size 8'' Design Pressure ANSI 1500 Construction Bolted Bonnet, Swing Type Connection Raised Face Flange Design & Manufacture BS 1868 End to End ASME B16.10 Connection ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material Carbon Steel Applicable Temp -29℃~+400℃ Media W.O.G. Dimension Class 1500 NPS in 2 2 1/2 3 4 6 8 10 12 DN mm 50 65 80 100 150 200 250 300 L-L1 (RF-BW) in 14-1/2 16-1/2 18-1/2 21-1/2 27-3/4 32-3/4 39 44-1/2 mm 368 419 470 546 705 832 991 1130 L2 (RTJ) in 14-5/8 16-5/8 18-5/8 21-5/8 28 33-1/8 39-3/8 45-1/8 mm 371 422 473 549 700 841 1000 1146 H (OPEN) in 12-1/4 12-1/4 13 14 15-3/4 20-7/8 22-1/16 25-5/8 mm 310 310 330 355 400 530 560 650 WT (kg) RF 69 93 140 232 490 990 1490 1970 BW 49 74 111 185 375 803 1250 1625

Double Flanged Check Valve Swing Type
Swing Type Non Return Valve DN150 PN40 RF Flange 1.0619

The swing type check valve, designed with PN40 RF flange, bolted cover, is made of cast steel 1.0619 and ss316 trim material. The full bore check valve can be manufactured per client's special requests. Quick Detail Type Non Return Valve ( Check Valve) Nominal Size DN 150 NominalPressure PN 40 Construction BB, Swing Type Disc, Exnternal Pin Connection Raised Face Flange Design & Manufacture DIN 3356 End to End EN 558 Connection EN 1092 Test & Inspection EN 12266 Body Material GS-C25 (1.0619) ApplicableTemp -29℃~+425℃ Media W.O.G. Material No Part Name Carbon steel to ASTM Alloy steel to ASTM Stainless steel to ASTM WCB LCB WC6 WC9  C5 CF8 CF8M CF3 CF3M 1 Body A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 2 Seat Ring A105 A350 LF2 A182 F11 A182 F22 A182 F5 A182 F304 A182 F316 A182 F304L A182 F316L 3 Disc nut A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 4 Disc washer A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 5 Disc A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 6 Hinge A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 7 Hinge pin A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 8 Yoke A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 9 Bonnet nut A194 2H A194 4 A194 7 A194 8 10 Bonnet bolt A193 B7 A193 L7 A193 B16 A193 B8 11 Gasket Stainless Steel Spiral Wound graphite or Stainless Steel Spiral Wound PTFE 12 Cover A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 13 Hook screw Steel 14 Name Plate Stainless steel or Aluminum 15 Rivet Stainless steel or Aluminum Other Material ( Alloy 20, ANSI 321, Monel Hastelloy, etc)are available on request Our Service A good customer service is as valuable as product itself. In Dervos, we will offer a full range of customer service to make you feel easy when doing business with us. Providing weekly production report When production begins, you will get production report weekly, so that you can have good command of product status and report to your customer at the meantime. Offering warranty of 18 months 18 months warranty period will be offered after shipment, no concern to purchase valve from Dervos. Providing solutions within 3-days for complaints All the complaints will be solved within 3 days, in this case, you can timely reply and solve problems for your customer, to relax them even when complaints happening.

Stainless Steel CF8 Check Valve
Stainless Steel Non Slam Swing Check Valve 8 Inch 150L

The stainless steel CF8 non return valve features in non slam type disc, ANSI 150 flange end, and full port design.  Quick Detail Type Non Return Valve ( Check Valve) Size 8'' DesignPressure Class 150 Construction Non Slam Type Connection RF Flange Design & Manufacture ASME B16.34 End to End ASME B16.10 Connection ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material A351 CF8 Trim Material SS304 Media W.O.G. Available Modifications for Dervos Valves -Valve Pressure -Valve Size -Reduced Bore & Full Bore -Body & Trim Material (Disc, Seat, Pin, Spring) -End Connection (Flange, BW, SW, Thread, Wafer, Lug) -Available Operation (Bare Stem, With Actuators) -Available Counterweight -Available Cylinder -Customizing Coating -Customizing Packaging Related Knowledge What is non-slam check valve? Water hammer is a hydraulic phenomenon that undergoes an abrupt change in its rate of flow and are caused by sudden shutting or slamming. Water hammer will reduce process efficiency, cause valve damage, gasket joint leaks and other problems. The non-slam check valve is designed to reduce water hammer. An internal spring can prevent the disc from slamming close.The design of a non-slam check valve could eliminate pressure flutuations, vibration and damges. Plus, the disc and spring experience minimal wear over time, which will largely extend the service lives of non-slam check compared to swing check valve.

Swing check valve
API 6D WCB RF Swing Type Check Valve CL600 4 inch 6 inch

API6D swing type check valve RF connnection bolted bonnet full pore WCB body, WCB+13Cr disc, A105+13Cr seat ring, WCB hinge. Suitable temperature in -29℃~+425℃ Quick Detail Type Swing Check Valve Size 4 inch-6 inch Design Pressure CL600 Construction BC, Swing type ConnectionType Flange OperationType - Body Material WCB DiscMaterial WCB+13Cr Hinge Material WCB Seat Material A105+13Cr Design Code API 6D Face to Face Dimension ASME B16.10 Test and Inspect API 598 Pressure & Temp ASME B16.34 Medium Water, Oil and Gas Origin China

Swing Check Valve
API 6D NPS 14 Cast Steel Swing Check Valve Bolted Cover 600LB

Chinese manufacturer Dervos offers 14 Inch swing check valves made according to API 6D. Other features cover CL300, RF End Connection, WCB body.

Swing Check Valve
Cast Steel NPS 6 Class 150 Swing Check Valve RF WCB Metallic Seated

The swing check valve is made of A216, a kind of WCB. Manufactured according to BS1868, the check valve is 6 inch and 150LB. And the valve is capable in working temperature between -19 to 425 degree Celsius.

Swing Check Valve
DIN Standard 1.0619 Swing Check Valve DN80 PN40

The swing check valve is made of 1.0619, a kind of carbon steel, as per DIN standard.The check valve is DN80 and PN40, or 3 inch and 300LB. And the valve is capable in working temperature between -19 to 425 degree Celsius.

Check Valve
Forged Steel Swing Check Valve API 602 1 Inch CL150 RF

The 1 inch swing check valve has the construction of bolted bonnet and RF flange end. The forged steel swing check valve is designed with reduced bore as per API 602. Dervos could also do customizing service as per clients’ requests on sizes, design ratings, materials, and standards and so on.

Check Valve
DIN 3840 Swing Check Valve DN200 PN40 Cast Steel

Made of high-quality casting, the DIN swing check valve has a cast steel body with bolted bonnet structure and flange connection. The valve is designed with good sealing performance and minimal water hammer effect.

Check Valve
DN400 PN10 Swing Check Valve Cast Steel WCB RF

DN400 PN10 check valve is made according to DIN standard. The valve body is made of WCB. It has the structural characteristics of swing type and structural length of 310mm. It has the connection mode of RF. This valve has a built-in damper, which is mainly used for shock absorption and energy dissipation.

Swing Check Valve
6" 1500LB Cast Steel Swing Check Valve WCB API6D BW

6" 1500LB swing check valve is made according to API 6D standard. The valve body is made of WCB. It has the structural characteristics of swing type. It has BW connection mode.

Swing Check Valve
1" 150LB Forged Steel Flange Swing Check Valve API 602 A105

1" 150LB swing check valve is made according to API 602 standard. The valve body is made of A105. It has the structural characteristics of bolt cover, swing type and full bore. Its connection mode is RF (Welded Flange).

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact