English

English

Get a Quote
Products

Hot Products

Company News

Line Blind Valve Interlocks and Position Verification: Preventing Unsafe Operation Under Pressure
Line Blind Valve Interlocks and Position Verification: Preventing Unsafe Operation Under Pressure
2026-09-18

A line blind valve creates positive isolation only after the solid plate is correctly positioned, fully restrained and capable of withstanding the process pressure. The dangerous part is the transition between the open and blinded states: many designs temporarily release the clamping force or expose part of the line while the plate moves. An interlock must therefore control an isolation sequence, not merely prevent the actuator from starting. A “closed” lamp, a limit-switch signal or a zero-pressure indication is useful evidence, but none of them independently proves that the line is safe to open.   Why Operating Sequence Matters More Than Actuator Type   Whether the line blind is manual, electric or hydraulic, it should not move until the process has been isolated, depressurized and drained. A powered actuator makes remote operation possible, but it also allows an incorrect command to be executed rapidly and from a location where the operator cannot see a release. A robust sequence normally requires: 1. Upstream and downstream block valves are closed and locked or otherwise secured. 2. The trapped section is vented or drained to a suitable disposal system. 3. Pressure has fallen below the project-defined permissive value. 4. A field operator or independent authorization confirms that the isolation arrangement is correct. 5. The line blind clamping mechanism is released. 6. The plate moves completely into the open or blind position. 7. The mechanism reclamps and mechanically secures the plate. 8. Final position and clamping status are recorded before process conditions are restored. This sequence matters because closing the adjacent valves does not remove trapped pressure. A blocked drain, leaking upstream valve, vaporizing liquid or thermal expansion can repressurize the cavity after an initial pressure reading.   AIG therefore recommends upstream isolation, bleed and pressure indication for line blind installations, with double block and bleed considered where a large hazardous inventory could be released. It also identifies pressure-sensing interlocks, controlled keys and secondary isolation verification as possible protection layers.   What Position Feedback Actually Proves   Position verification should answer three separate questions: · Is the solid or open plate in the intended location? · Is the plate fully clamped and mechanically retained? · Is the surrounding process condition safe for movement? These are different states and should not be represented by one shared switch. A limit switch normally confirms that the component driving the switch has reached a calibrated endpoint. It does not automatically prove that the blind plate followed the drive mechanism, that the plate is centred between the seats, or that the clamping load is adequate. A loose cam, bent bracket, damaged linkage or incorrectly adjusted switch can produce...

Blind Valve for Pipeline Maintenance: Positive Isolation Requirements Before Line Opening
Blind Valve for Pipeline Maintenance: Positive Isolation Requirements Before Line Opening
2026-09-10

Before a pipeline is opened, a blind valve should be treated as one part of an isolation system, not as a permit by itself. Its value is that it can place a visible physical barrier in the line, but that barrier only becomes meaningful when the site has also isolated, depressurized, drained, vented, locked, tagged, tested, and verified the correct section of piping.   Line opening is the moment when weak isolation becomes real. A closed valve may pass. A bleed point may be plugged. A drawing may be outdated. Liquid may remain trapped in a low point. Gas may migrate from an unexpected connection. This is why positive isolation for pipeline maintenance has to be judged as a chain of proof, not a single valve feature.   The Isolation Boundary Must Be Proven on the Drawing and in the Field   The first requirement is knowing exactly what is being isolated. Maintenance teams usually start from the P&ID or isolation plan, but the field verification is just as important. Tie-ins, bypasses, drains, vents, sample points, small-bore branches, equalizing lines, instrument connections, and thermal relief paths can all create energy routes around the expected isolation point.   A blind valve installed in the correct location can give strong physical isolation. Installed on the wrong side of a branch connection, it may protect the main line while leaving the work face exposed to pressure or hazardous material from a side path. That is not a valve failure; it is an isolation boundary failure.   Before line opening, the isolation plan should identify the upstream and downstream sources, the section to be opened, all possible re-pressurization routes, and the exact valve position required. The field check should confirm tag numbers, flow direction, blind position, locking status, and whether the valve can be seen and reached safely.   Positive Isolation Is More Than Seat Leakage   A blind valve differs from a normal shutoff valve because it uses a solid blind plate, spectacle plate, or sliding/swinging blind mechanism to block the bore. This reduces reliance on seat tightness alone. For maintenance work involving flange breaking, equipment opening, hot work, confined-space entry, or hazardous media, that physical barrier can be more defensible than a closed gate, globe, or ball valve.   Still, the phrase “positive isolation” should not be used loosely. The blind must be in the correct position, fully seated, mechanically restrained, locked or tagged according to the site procedure, and confirmed by position indication that maintenance personnel can understand. If the mechanism is stiff, partly engaged, poorly marked, or difficult to verify from the work area, the valve’s theoretical advantage becomes weaker.   The seal arrangement also matters. Some line blind valves rely on resilient seals, graphite seals, metal seating surfaces, or combined sealing designs depending on temperature, pressure, and ...

Line Blind Valve vs Double Block and Bleed: Choosing Positive Isolation for Refinery Shutdowns
Line Blind Valve vs Double Block and Bleed: Choosing Positive Isolation for Refinery Shutdowns
2026-09-04

In refinery shutdowns, the choice between a line blind valve and double block and bleed is not a contest between one safe method and one unsafe method. Both can be valid isolation methods, but they control risk in different ways.   A line blind valve creates isolation by moving a solid blind plate into the pipeline bore. The isolation is visible and mechanical. A double block and bleed arrangement isolates by closing two barriers and opening a bleed or vent between them, so trapped pressure or leakage can be released or monitored. The engineering question is not only “which one seals better?” It is “what work will happen after isolation, and how much reliance can the site accept on valve seats, bleed monitoring, and procedure control?”   Shutdown Work Changes the Isolation Standard   Routine instrument work, sampling maintenance, or short inspection tasks may justify a different isolation method from hot work, vessel entry, flange breaking, or long-duration turnaround maintenance. In a refinery, the same hydrocarbon line may be low-risk in one task and high-risk in another because the exposure changes. A DBB arrangement is useful when the work needs fast, verifiable valve isolation without moving a blind plate into the bore. The bleed point gives operators a way to confirm whether pressure is trapped between the isolation points or whether one of the seats may be passing. For many operating teams, that makes DBB practical for frequent or temporary isolation where breaking containment would add more work and more exposure. A line blind valve becomes stronger when the job needs visible physical separation from a live or potentially live system. If the isolated equipment will be opened, entered, welded, cleaned, or left out of service during a shutdown window, a solid blind plate reduces dependence on seat tightness. The valve still needs proper operation, locking, marking, and testing, but the core barrier is no longer only a seating surface.   Where DBB Earns Its Place   DBB is attractive because it can reduce downtime. A compact DBB valve or a two-valve DBB arrangement can isolate, bleed, and verify without removing a spool or installing a separate blind flange. For refinery units with many small-bore connections, drains, vents, sampling points, or instrument take-offs, that speed matters. The risk with DBB is that its safety case still depends on seat integrity, correct bleed routing, pressure monitoring, and disciplined lockout practice. If the bleed is not routed to a safe location, it may create a release hazard. If operators close two valves but do not prove the bleed, the system may only look isolated. If the valves have seat damage from coke, catalyst fines, thermal cycling, corrosion, or debris, the bleed point may reveal leakage rather than eliminate it. This is why DBB should be described clearly in the shutdown plan. Does the project mean two separate inline isolation valves with a drain...

Swing Check Valve
加载中...

1" 150LB Forged Steel Flange Swing Check Valve API 602 A105

1" 150LB swing check valve is made according to API 602 standard. The valve body is made of A105. It has the structural characteristics of bolt cover, swing type and full bore. Its connection mode is RF (Welded Flange).

  • Payment:

    30% when order confirmed, 70% before shipment
  • Product Origin:

    China
  • Color:

    Customization
  • Shipping Port:

    Shanghai, China
  • Lead Time:

    30~60 days Ex Works after order confirmation
  • Material:

    A105
Inquiry now
Product Detail

Product Description

Type

Swing Check Valve

Size

1"

Pressure

150LB

Connection

RF (Welded Flange)

Body Material

A105

Design Norm

API 602

Face to Face

ASME B16.10

Flange Dimension

ASME B16.5

Material

AISI/AST,

Test & Inspection Code

API 598

Applicable Medium

Steam

Features

1. All welds of the valve (jacket and end flange) have been tested by PT coloring, and there is a factory report;

2. With a jacket made of SS304, the steam in the jacket is 204 degrees Celsius;

3. The valve flange is an enlarged flange, the 1-inch valve has a 2" 150LB flange.

Technical Drawing

Dimension Checking

Pressure Testing

Nameplate & Packing

Inspection report


Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
BS 1868 Swing Type Check Valve
8 Inch Swing Check Valve 1500 LB WCB Flanged BB BS 1868

The 8 inch non return check valve conforms to BS 1868 design code, with bolted bonnet and swing type disc. The flanged check valve is made of carbon steel A216 WCB. Design Feature 1.BB: bolted bonnet 2.Swing type disc 3.Reduced bore design 4.Superior flow rates 5.Minimized friction loss 6.Standard trim material for selection 7.External or internal hinge pin available on request 8.Cylinder and counter weight available on request 9.Bare stem and actuators are available on request Quick Detail Type Check Valve Size 8'' Design Pressure ANSI 1500 Construction Bolted Bonnet, Swing Type Connection Raised Face Flange Design & Manufacture BS 1868 End to End ASME B16.10 Connection ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material Carbon Steel Applicable Temp -29℃~+400℃ Media W.O.G. Dimension Class 1500 NPS in 2 2 1/2 3 4 6 8 10 12 DN mm 50 65 80 100 150 200 250 300 L-L1 (RF-BW) in 14-1/2 16-1/2 18-1/2 21-1/2 27-3/4 32-3/4 39 44-1/2 mm 368 419 470 546 705 832 991 1130 L2 (RTJ) in 14-5/8 16-5/8 18-5/8 21-5/8 28 33-1/8 39-3/8 45-1/8 mm 371 422 473 549 700 841 1000 1146 H (OPEN) in 12-1/4 12-1/4 13 14 15-3/4 20-7/8 22-1/16 25-5/8 mm 310 310 330 355 400 530 560 650 WT (kg) RF 69 93 140 232 490 990 1490 1970 BW 49 74 111 185 375 803 1250 1625

Double Flanged Check Valve Swing Type
Swing Type Non Return Valve DN150 PN40 RF Flange 1.0619

The swing type check valve, designed with PN40 RF flange, bolted cover, is made of cast steel 1.0619 and ss316 trim material. The full bore check valve can be manufactured per client's special requests. Quick Detail Type Non Return Valve ( Check Valve) Nominal Size DN 150 NominalPressure PN 40 Construction BB, Swing Type Disc, Exnternal Pin Connection Raised Face Flange Design & Manufacture DIN 3356 End to End EN 558 Connection EN 1092 Test & Inspection EN 12266 Body Material GS-C25 (1.0619) ApplicableTemp -29℃~+425℃ Media W.O.G. Material No Part Name Carbon steel to ASTM Alloy steel to ASTM Stainless steel to ASTM WCB LCB WC6 WC9  C5 CF8 CF8M CF3 CF3M 1 Body A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 2 Seat Ring A105 A350 LF2 A182 F11 A182 F22 A182 F5 A182 F304 A182 F316 A182 F304L A182 F316L 3 Disc nut A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 4 Disc washer A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 5 Disc A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 6 Hinge A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 7 Hinge pin A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 8 Yoke A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 9 Bonnet nut A194 2H A194 4 A194 7 A194 8 10 Bonnet bolt A193 B7 A193 L7 A193 B16 A193 B8 11 Gasket Stainless Steel Spiral Wound graphite or Stainless Steel Spiral Wound PTFE 12 Cover A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 13 Hook screw Steel 14 Name Plate Stainless steel or Aluminum 15 Rivet Stainless steel or Aluminum Other Material ( Alloy 20, ANSI 321, Monel Hastelloy, etc)are available on request Our Service A good customer service is as valuable as product itself. In Dervos, we will offer a full range of customer service to make you feel easy when doing business with us. Providing weekly production report When production begins, you will get production report weekly, so that you can have good command of product status and report to your customer at the meantime. Offering warranty of 18 months 18 months warranty period will be offered after shipment, no concern to purchase valve from Dervos. Providing solutions within 3-days for complaints All the complaints will be solved within 3 days, in this case, you can timely reply and solve problems for your customer, to relax them even when complaints happening.

Stainless Steel CF8 Check Valve
Stainless Steel Non Slam Swing Check Valve 8 Inch 150L

The stainless steel CF8 non return valve features in non slam type disc, ANSI 150 flange end, and full port design.  Quick Detail Type Non Return Valve ( Check Valve) Size 8'' DesignPressure Class 150 Construction Non Slam Type Connection RF Flange Design & Manufacture ASME B16.34 End to End ASME B16.10 Connection ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material A351 CF8 Trim Material SS304 Media W.O.G. Available Modifications for Dervos Valves -Valve Pressure -Valve Size -Reduced Bore & Full Bore -Body & Trim Material (Disc, Seat, Pin, Spring) -End Connection (Flange, BW, SW, Thread, Wafer, Lug) -Available Operation (Bare Stem, With Actuators) -Available Counterweight -Available Cylinder -Customizing Coating -Customizing Packaging Related Knowledge What is non-slam check valve? Water hammer is a hydraulic phenomenon that undergoes an abrupt change in its rate of flow and are caused by sudden shutting or slamming. Water hammer will reduce process efficiency, cause valve damage, gasket joint leaks and other problems. The non-slam check valve is designed to reduce water hammer. An internal spring can prevent the disc from slamming close.The design of a non-slam check valve could eliminate pressure flutuations, vibration and damges. Plus, the disc and spring experience minimal wear over time, which will largely extend the service lives of non-slam check compared to swing check valve.

Swing check valve
API 6D WCB RF Swing Type Check Valve CL600 4 inch 6 inch

API6D swing type check valve RF connnection bolted bonnet full pore WCB body, WCB+13Cr disc, A105+13Cr seat ring, WCB hinge. Suitable temperature in -29℃~+425℃ Quick Detail Type Swing Check Valve Size 4 inch-6 inch Design Pressure CL600 Construction BC, Swing type ConnectionType Flange OperationType - Body Material WCB DiscMaterial WCB+13Cr Hinge Material WCB Seat Material A105+13Cr Design Code API 6D Face to Face Dimension ASME B16.10 Test and Inspect API 598 Pressure & Temp ASME B16.34 Medium Water, Oil and Gas Origin China

Swing Check Valve
API 6D NPS 14 Cast Steel Swing Check Valve Bolted Cover 600LB

Chinese manufacturer Dervos offers 14 Inch swing check valves made according to API 6D. Other features cover CL300, RF End Connection, WCB body.

Swing Check Valve
Cast Steel NPS 6 Class 150 Swing Check Valve RF WCB Metallic Seated

The swing check valve is made of A216, a kind of WCB. Manufactured according to BS1868, the check valve is 6 inch and 150LB. And the valve is capable in working temperature between -19 to 425 degree Celsius.

Swing Check Valve
DIN Standard 1.0619 Swing Check Valve DN80 PN40

The swing check valve is made of 1.0619, a kind of carbon steel, as per DIN standard.The check valve is DN80 and PN40, or 3 inch and 300LB. And the valve is capable in working temperature between -19 to 425 degree Celsius.

Check Valve
Forged Steel Swing Check Valve API 602 1 Inch CL150 RF

The 1 inch swing check valve has the construction of bolted bonnet and RF flange end. The forged steel swing check valve is designed with reduced bore as per API 602. Dervos could also do customizing service as per clients’ requests on sizes, design ratings, materials, and standards and so on.

Check Valve
DIN 3840 Swing Check Valve DN200 PN40 Cast Steel

Made of high-quality casting, the DIN swing check valve has a cast steel body with bolted bonnet structure and flange connection. The valve is designed with good sealing performance and minimal water hammer effect.

Check Valve
DN400 PN10 Swing Check Valve Cast Steel WCB RF

DN400 PN10 check valve is made according to DIN standard. The valve body is made of WCB. It has the structural characteristics of swing type and structural length of 310mm. It has the connection mode of RF. This valve has a built-in damper, which is mainly used for shock absorption and energy dissipation.

Swing Check Valve
6" 1500LB Cast Steel Swing Check Valve WCB API6D BW

6" 1500LB swing check valve is made according to API 6D standard. The valve body is made of WCB. It has the structural characteristics of swing type. It has BW connection mode.

Swing Check Valve
API 6" 150LB Cast Steel Swing Check Valve RF BC WCB

6" 150LB check valve is made according to API 6D standard. The valve body is made of WCB. It has the structural characteristics of swing type and external pin. Its connection mode is RF.

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact