English

English

Get a Quote
Products

Hot Products

Company News

Can Oil Pass Through a Strainer? How Pre-Filtration Works in Lubrication Systems
Can Oil Pass Through a Strainer? How Pre-Filtration Works in Lubrication Systems
2025-05-20

In any efficient and reliable lubrication system, oil cleanliness is a core factor affecting equipment lifespan and operational efficiency. Strainers, as the front-line filtration devices in lubrication systems, play a critical role in pre-filtration. However, engineers and operators often raise the following questions: Can oil pass through strainers smoothly? What exactly is the function of a strainer? How does it differ from subsequent fine filters?   This article systematically explains the role of strainers in lubrication systems, covering their working principles, pre-filtration objectives, and practical applications across different systems.   1. Can Oil Pass Through a Strainer?   Answer: Yes, but with limitations.   (1) Strainer Structure Allows Oil Flow A strainer is fundamentally a low-precision filter made of stainless steel mesh or perforated metal plates. It features uniform pores, typically sized between 80–500 μm (micrometers), allowing most clean oil to flow through unimpeded.   (2) Contaminants Are Blocked Particles such as metal shavings, seal fragments, and carbon deposits in the oil are intercepted by the strainer, preventing them from entering the oil pump or other critical components.   (3) Oil Temperature and Viscosity Affect Flow Efficiency Low temperatures or high-viscosity oil may reduce flow rates or even cause blockages. This is one reason for low oil pressure during system startup.   2. Objectives and Significance of Pre-Filtration   (1) Protecting the Oil Pump Internal pump components (gears, impellers, or plungers) are highly sensitive to solid particles. Pre-filtration prevents particles from entering the pump, avoiding premature wear or seizure.   (2) Reducing Load on Primary Filters By intercepting large contaminants, strainers allow primary filters (e.g., oil filter cartridges) to focus on finer impurities, extending their service life and maintaining stable system flow.   (3) Lowering System Failure Rates Pre-filtration reduces risks such as pump failure, orifice blockages, and lubrication breakdown caused by foreign particles, enhancing overall system reliability.   3. Typical Applications of Pre-Filtration Devices   Application System Strainer Installation Position Strainer Type Internal Combustion Engine Lubrication Oil sump → Pump inlet Coarse metal strainer Hydraulic Systems Tank outlet → Pump suction port Suction strainer or basket strainer Turbine Lubrication Systems Pump inlet Dual-chamber switchable suction strainer Transmission/Clutch Systems Oil sump → Circulation pump inlet Perforated plate + magnetic strainer   4. Design and Usage Considerations for Strainers   (1) Pore Size Selection Must Align with System Precision Requirements 80–100 μm: Typical for engine oil systems. 150–300 μm: Used in hydraulic equipment. >400 μm:  Suitable for low-pressure or open-loop systems.   (2...

Are Ball Valves Suitable for Water Systems? A Practical Guide for Engineers & Installers
Are Ball Valves Suitable for Water Systems? A Practical Guide for Engineers & Installers
2025-04-30

Ball valves, with their simple structure, easy operation, and excellent sealing performance, have become widely used control components in both industrial and residential sectors. Particularly in water supply systems, an increasing number of engineers and installers are choosing ball valves as the primary fluid control device. But are ball valves truly suitable for water systems? How should one properly select and install them to ensure long-term stable operation? This article provides a comprehensive overview from the perspectives of structural principles, performance characteristics, and application recommendations. 1. Advantages of Ball Valves in Water Systems (1) Quick Opening and Closing Ball valves can complete the opening and closing operation with a simple 90° rotation, making them easy to operate and highly responsive—ideal for emergency situations or water systems that require frequent switching.   (2) Excellent Sealing Performance High-quality ball valves are equipped with PTFE or reinforced sealing materials, enabling zero leakage. They are particularly suitable for water supply systems in residential buildings, commercial complexes, and industrial facilities where sealing performance is critical.   (3) Compact Structure and Space-Saving Compared to gate valves or globe valves, ball valves occupy less space and offer flexible installation, making them ideal for water modules with high equipment integration.   (4) Strong Corrosion Resistance Ball valves made of stainless steel, brass, or plastic materials (such as UPVC) offer excellent corrosion resistance, capable of handling various water qualities (soft water, hard water, reclaimed water) and different additives.   2. Application Scenarios Analysis Ball valves are suitable for the following types of water systems: (1) Domestic Water Systems: Such as internal building water supply, point-of-use control for sanitary fixtures, and garden irrigation systems. (2) Industrial Water Systems: Such as cooling water circulation systems, boiler feedwater systems, and water supply for cleaning equipment. (3) Water Treatment Systems: Including reverse osmosis pretreatment, greywater recycling, and wastewater transfer processes. (4) Special Applications: High-pressure hot water systems or cleaning water containing chemical additives.   However, caution should be exercised in the following scenarios: (1) High-Frequency Modulation Conditions Standard ball valves are not suitable for precise flow regulation. It is recommended to use V-port ball valves or control-type electric ball valves. (2) Water Containing Sand, Gravel, or High Levels of Suspended Solids A Y-strainer should be installed to prevent particle blockage or damage to the sealing surfaces. (3) High-Temperature Hot Water Systems High-temperature ball valves with metal sealing structures should be selected to prevent seal aging and deformation.   3. Key Selection Criteria To ensure stable operation o...

What Causes Ball Valve Failure? 5 Common Issues and How to Prevent Them
What Causes Ball Valve Failure? 5 Common Issues and How to Prevent Them
2025-04-11

Ball valves are widely used industrial flow control components, commonly found in applications such as water treatment, oil and gas, chemical processing, HVAC systems, and the food and pharmaceutical industries. Thanks to their compact structure, quick shut-off capability, and excellent sealing performance, ball valves play a critical role in various fluid systems. However, even the most reliable ball valve can encounter failures after prolonged operation. When a ball valve fails, it can compromise the stability of the entire system and, in severe cases, lead to media leakage or even safety incidents. Therefore, understanding the root causes of ball valve failure and implementing effective preventive measures is essential for engineers and maintenance personnel.   1. Seal Failure Cause: Seal failure in ball valves is often caused by seat wear, debris accumulation, or aging of sealing materials. This issue is especially common in high-temperature, high-pressure, or corrosive media environments. Prevention Tips: To extend the service life of the seal, choose ball valves with PTFE or metal seats that are compatible with the process media. Regularly clean the seat area and establish a replacement schedule based on the operating conditions.   2. Corrosion or Scratches on the Ball Surface Cause: When a ball valve is used with media containing acids, alkalis, high salt content, or abrasive particles, improper material selection can lead to corrosion, pitting, or surface scratches. These issues reduce sealing performance and affect smooth operation. Prevention Tips: Select stainless steel ball valves (such as 304 or 316 grades) or special alloy ball valves based on the specific media characteristics. Additionally, install a strainer or filter to minimize solid particle intrusion and protect the valve internals.   3. Stem Breakage or Seizure Cause: The valve stem, which transmits torque to the ball, may experience metal fatigue and fracture under frequent operation or excessive torque. Seizure can also occur due to bearing wear or lack of lubrication. In some low-quality ball valves, insufficient structural design margin further increases the risk of stem failure. Prevention Tips: Use ball valves with blow-out proof stem designs to enhance operational safety. Ensure that operating torque stays within the valve’s rated limits, and apply lubricant regularly to reduce friction and wear, extending service life.   4. Improper Installation or Operation Cause: Human errors such as incorrect installation direction, loose flange connections, or frequent forceful operation are major contributors to early ball valve failure. In the case of electric or pneumatic ball valves, signal control errors can also lead to misoperation or valve jamming. Prevention Tips: Always follow the manufacturer’s installation guidelines, ensure proper alignment and secure flange connections. Install limit switches and torque protection devices to safeguard...

10 150LB Swing Check Valve, RF Connection, Body WCB, API 6D
加载中...

10" 150LB Swing Check Valve, RF Connection, Body WCB, API 6D

10" 150LB swing check valve is made according to API 6D standard. The valve body is made of ASTM A216 WCB. It has the structural characteristics of swing type, built-in type, fully open. Its connection mode is RF.

  • Payment:

    30% when order confirmed, 70% before shipment
  • Product Origin:

    China
  • Color:

    Customization
  • Shipping Port:

    Shanghai, China
  • Lead Time:

    30~60 days Ex Works after order confirmation
  • Material:

    ASTM A216 WCB
Inquiry now
Product Detail


Product Description

Type

Swing Check Valve

Size

10"

Pressure

150LB

Connection

RF

Body Material

ASTM A216 WCB

Design Norm

API 6D

Temperature and Pressure

ASME B16.34

Face to Face Dimensions

ASME B16.10

Flange Ends Dimensions

ASME B16.5

Test & Inspection Code

API 6D

Temperature

-29 ~ 425°C

Applicable Medium

Water, Oil and Gas


Features

1. It is designed for one-way flow, where the disc swings open or closed to prevent backflow, ensuring the safety of pipelines and equipment;

2. With a streamlined internal passage and simple design, it offers minimal fluid resistance, reducing energy consumption.

Technical Drawing

10" 150LB Swing Check Valve, RF Connection, Body WCB, API 6D

Dimension Checking

10" 150LB Swing Check Valve, RF Connection, Body WCB, API 6D

Pressure Testing

10" 150LB Swing Check Valve, RF Connection, Body WCB, API 6D

Painting

10" 150LB Swing Check Valve, RF Connection, Body WCB, API 6D

Nameplate & Packing

10" 150LB Swing Check Valve, RF Connection, Body WCB, API 6D

Inspection report

10" 150LB Swing Check Valve, RF Connection, Body WCB, API 6D10" 150LB Swing Check Valve, RF Connection, Body WCB, API 6D10" 150LB Swing Check Valve, RF Connection, Body WCB, API 6D10" 150LB Swing Check Valve, RF Connection, Body WCB, API 6D

Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
BS 1868 Swing Type Check Valve
8 Inch Swing Check Valve 1500 LB WCB Flanged BB BS 1868

The 8 inch non return check valve conforms to BS 1868 design code, with bolted bonnet and swing type disc. The flanged check valve is made of carbon steel A216 WCB. Design Feature 1.BB: bolted bonnet 2.Swing type disc 3.Reduced bore design 4.Superior flow rates 5.Minimized friction loss 6.Standard trim material for selection 7.External or internal hinge pin available on request 8.Cylinder and counter weight available on request 9.Bare stem and actuators are available on request Quick Detail Type Check Valve Size 8'' Design Pressure ANSI 1500 Construction Bolted Bonnet, Swing Type Connection Raised Face Flange Design & Manufacture BS 1868 End to End ASME B16.10 Connection ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material Carbon Steel Applicable Temp -29℃~+400℃ Media W.O.G. Dimension Class 1500 NPS in 2 2 1/2 3 4 6 8 10 12 DN mm 50 65 80 100 150 200 250 300 L-L1 (RF-BW) in 14-1/2 16-1/2 18-1/2 21-1/2 27-3/4 32-3/4 39 44-1/2 mm 368 419 470 546 705 832 991 1130 L2 (RTJ) in 14-5/8 16-5/8 18-5/8 21-5/8 28 33-1/8 39-3/8 45-1/8 mm 371 422 473 549 700 841 1000 1146 H (OPEN) in 12-1/4 12-1/4 13 14 15-3/4 20-7/8 22-1/16 25-5/8 mm 310 310 330 355 400 530 560 650 WT (kg) RF 69 93 140 232 490 990 1490 1970 BW 49 74 111 185 375 803 1250 1625

Double Flanged Check Valve Swing Type
Swing Type Non Return Valve DN150 PN40 RF Flange 1.0619

The swing type check valve, designed with PN40 RF flange, bolted cover, is made of cast steel 1.0619 and ss316 trim material. The full bore check valve can be manufactured per client's special requests. Quick Detail Type Non Return Valve ( Check Valve) Nominal Size DN 150 NominalPressure PN 40 Construction BB, Swing Type Disc, Exnternal Pin Connection Raised Face Flange Design & Manufacture DIN 3356 End to End EN 558 Connection EN 1092 Test & Inspection EN 12266 Body Material GS-C25 (1.0619) ApplicableTemp -29℃~+425℃ Media W.O.G. Material No Part Name Carbon steel to ASTM Alloy steel to ASTM Stainless steel to ASTM WCB LCB WC6 WC9  C5 CF8 CF8M CF3 CF3M 1 Body A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 2 Seat Ring A105 A350 LF2 A182 F11 A182 F22 A182 F5 A182 F304 A182 F316 A182 F304L A182 F316L 3 Disc nut A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 4 Disc washer A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 5 Disc A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 6 Hinge A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 7 Hinge pin A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 8 Yoke A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 9 Bonnet nut A194 2H A194 4 A194 7 A194 8 10 Bonnet bolt A193 B7 A193 L7 A193 B16 A193 B8 11 Gasket Stainless Steel Spiral Wound graphite or Stainless Steel Spiral Wound PTFE 12 Cover A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 13 Hook screw Steel 14 Name Plate Stainless steel or Aluminum 15 Rivet Stainless steel or Aluminum Other Material ( Alloy 20, ANSI 321, Monel Hastelloy, etc)are available on request Our Service A good customer service is as valuable as product itself. In Dervos, we will offer a full range of customer service to make you feel easy when doing business with us. Providing weekly production report When production begins, you will get production report weekly, so that you can have good command of product status and report to your customer at the meantime. Offering warranty of 18 months 18 months warranty period will be offered after shipment, no concern to purchase valve from Dervos. Providing solutions within 3-days for complaints All the complaints will be solved within 3 days, in this case, you can timely reply and solve problems for your customer, to relax them even when complaints happening.

Stainless Steel CF8 Check Valve
Stainless Steel Non Slam Swing Check Valve 8 Inch 150L

The stainless steel CF8 non return valve features in non slam type disc, ANSI 150 flange end, and full port design.  Quick Detail Type Non Return Valve ( Check Valve) Size 8'' DesignPressure Class 150 Construction Non Slam Type Connection RF Flange Design & Manufacture ASME B16.34 End to End ASME B16.10 Connection ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material A351 CF8 Trim Material SS304 Media W.O.G. Available Modifications for Dervos Valves -Valve Pressure -Valve Size -Reduced Bore & Full Bore -Body & Trim Material (Disc, Seat, Pin, Spring) -End Connection (Flange, BW, SW, Thread, Wafer, Lug) -Available Operation (Bare Stem, With Actuators) -Available Counterweight -Available Cylinder -Customizing Coating -Customizing Packaging Related Knowledge What is non-slam check valve? Water hammer is a hydraulic phenomenon that undergoes an abrupt change in its rate of flow and are caused by sudden shutting or slamming. Water hammer will reduce process efficiency, cause valve damage, gasket joint leaks and other problems. The non-slam check valve is designed to reduce water hammer. An internal spring can prevent the disc from slamming close.The design of a non-slam check valve could eliminate pressure flutuations, vibration and damges. Plus, the disc and spring experience minimal wear over time, which will largely extend the service lives of non-slam check compared to swing check valve.

Swing check valve
API 6D WCB RF Swing Type Check Valve CL600 4 inch 6 inch

API6D swing type check valve RF connnection bolted bonnet full pore WCB body, WCB+13Cr disc, A105+13Cr seat ring, WCB hinge. Suitable temperature in -29℃~+425℃ Quick Detail Type Swing Check Valve Size 4 inch-6 inch Design Pressure CL600 Construction BC, Swing type ConnectionType Flange OperationType - Body Material WCB DiscMaterial WCB+13Cr Hinge Material WCB Seat Material A105+13Cr Design Code API 6D Face to Face Dimension ASME B16.10 Test and Inspect API 598 Pressure & Temp ASME B16.34 Medium Water, Oil and Gas Origin China

Swing Check Valve
API 6D NPS 14 Cast Steel Swing Check Valve Bolted Cover 600LB

Chinese manufacturer Dervos offers 14 Inch swing check valves made according to API 6D. Other features cover CL300, RF End Connection, WCB body.

Swing Check Valve
Cast Steel NPS 6 Class 150 Swing Check Valve RF WCB Metallic Seated

The swing check valve is made of A216, a kind of WCB. Manufactured according to BS1868, the check valve is 6 inch and 150LB. And the valve is capable in working temperature between -19 to 425 degree Celsius.

Swing Check Valve
DIN Standard 1.0619 Swing Check Valve DN80 PN40

The swing check valve is made of 1.0619, a kind of carbon steel, as per DIN standard.The check valve is DN80 and PN40, or 3 inch and 300LB. And the valve is capable in working temperature between -19 to 425 degree Celsius.

Check Valve
Forged Steel Swing Check Valve API 602 1 Inch CL150 RF

The 1 inch swing check valve has the construction of bolted bonnet and RF flange end. The forged steel swing check valve is designed with reduced bore as per API 602. Dervos could also do customizing service as per clients’ requests on sizes, design ratings, materials, and standards and so on.

Check Valve
DIN 3840 Swing Check Valve DN200 PN40 Cast Steel

Made of high-quality casting, the DIN swing check valve has a cast steel body with bolted bonnet structure and flange connection. The valve is designed with good sealing performance and minimal water hammer effect.

Check Valve
DN400 PN10 Swing Check Valve Cast Steel WCB RF

DN400 PN10 check valve is made according to DIN standard. The valve body is made of WCB. It has the structural characteristics of swing type and structural length of 310mm. It has the connection mode of RF. This valve has a built-in damper, which is mainly used for shock absorption and energy dissipation.

Swing Check Valve
6" 1500LB Cast Steel Swing Check Valve WCB API6D BW

6" 1500LB swing check valve is made according to API 6D standard. The valve body is made of WCB. It has the structural characteristics of swing type. It has BW connection mode.

Swing Check Valve
1" 150LB Forged Steel Flange Swing Check Valve API 602 A105

1" 150LB swing check valve is made according to API 602 standard. The valve body is made of A105. It has the structural characteristics of bolt cover, swing type and full bore. Its connection mode is RF (Welded Flange).