English

English

Get a Quote
Products

Hot Products

Company News

Will a Line Blind Spill Product During Changeover? Open vs Non-Spill vs Enclosed Designs
Will a Line Blind Spill Product During Changeover? Open vs Non-Spill vs Enclosed Designs
2026-10-16

Yes, an open-body line blind can release residual product when it changes between the open and blind positions. A non-spill design does not make that residue disappear; it catches the liquid in a partial enclosure and directs it to a drain. An enclosed design can provide better control of liquid and vapour, but only when its housing, drain, vent and purge connections are engineered for the service. None of these labels should be read as permission to move the blind under live line pressure.   Why Product Can Escape During Changeover   When a line blind is fully clamped, its seals contain the process and the solid plate provides positive isolation in the blind position. Changeover is different. The sealing faces must separate before the spectacle or sliding plate can move. During that interval, the body cavity and plate path may be open to the surrounding area.   The line should already be isolated, depressurised and drained, but “drained” rarely means perfectly dry. Liquid can remain as a film on the plate, collect in the lower body, or sit in a poorly drained pipe pocket. Gas service may leave flammable, toxic or odorous vapour. The amount released therefore depends as much on piping layout and the shutdown procedure as on the line blind itself.   The Three Designs Manage Residue Differently   Open-body design   Residual liquid can drip from the exposed plate path into a temporary tray or the work area, while vapour disperses locally. This arrangement can suit water, steam condensate or other manageable media where easy access and visual inspection matter. It presents the highest potential for floor contamination and operator exposure.   Non-spill design   A bottom-and-side cover catches drips and sends them to a drain or recovery container; the top may remain open. This design is commonly considered for fuel terminals, marine service and liquid duties where ground or deck contamination must be controlled. It reduces dripping but may not contain vapour, and a blocked drain defeats its purpose.   Enclosed design   A housing surrounds more or all of the plate travel and may connect to a closed drain, purge, vent, flare or vapour-recovery system. It is better suited to toxic, flammable, odorous or environmentally sensitive service requiring controlled containment. The tradeoff is greater complexity in purging, inspection and maintenance, together with the need to manage trapped pressure deliberately.   These names are not perfectly standardised across manufacturers. One supplier's “non-spill” model may be open at the top, while another product described as enclosed may use a more complete casing. The RFQ should show the enclosure arrangement and identify every opening rather than relying on the product name.   Non-Spill Does Not Automatically Mean Zero Release   For a liquid with low volatility, catching the remaining drops and routing them into a closed contai...

How Often Do You Open the Pipeline? When Is a Line Blind Valve Worth Installing?
How Often Do You Open the Pipeline? When Is a Line Blind Valve Worth Installing?
2026-09-30

A line blind valve is worth evaluating when a pipeline is blinded several times a year, or when one conventional changeover causes hours of shutdown, lifting work or significant exposure to hazardous residue. No universal cycle count guarantees payback. A large critical line operated twice a year may justify the investment, while a small accessible line operated monthly may not.   The decision should be based on the cost and risk of each complete isolation event, not frequency alone.   There Is No Standard “Two Operations per Year” Rule   Some suppliers use one or two annual changeovers as a screening threshold. That can start a discussion, but it is not an engineering rule. Frequency has very different consequences on a DN50 utility line and a DN600 process-gas main.   For a preliminary review, the following bands are useful but not mandatory: Blinding frequency  Initial interpretation Once per major turnaround or less A removable blind or spectacle blind is often more economical. One to three times per year Compare labor, lifting, outage duration and medium risk carefully. Quarterly to monthly A quick-action line blind is normally a strong candidate. Weekly or more often Purpose-built or automated isolation deserves detailed review; also confirm that a line blind is suitable for the required cycle duty.   A low operating frequency can still support installation when every event requires scaffolding, a crane, several pipefitters or a long production interruption. Conversely, frequent operation does not justify a line blind if the process cannot accommodate its pressure, temperature, materials or maintenance needs.   Count the Complete Changeover   Traditional blinding is more than moving a plate. After the line is made safe, workers loosen bolting, spread the flange joint, handle the blind or spacer, replace gaskets, restore alignment, tighten the joint and complete leak checks. Large sizes add rigging and access equipment.   A quick-action line blind keeps the spectacle or sliding plate supported inside the installed assembly. Manufacturer literature commonly reports one-person changeover in minutes rather than the man-hours needed for conventional flange work. Those figures are useful for screening, but the project calculation should use the plant’s own procedures and recorded shutdown times.   Use a simple comparison: Annual avoided cost = operations per year x cost avoided per operation   Avoided cost may include pipefitter hours, rigging, scaffolding, gaskets and bolting, leak testing and the production value of saved time. Keep categories separate to avoid double counting. Compare the annual saving with the line blind’s additional installed price and maintenance cost.   Risk Can Matter More Than Simple Payback   Repeated flange separation creates opportunities for residual-medium exposure, damaged flange faces, poor alignment and inconsistent bolt load...

Blind Valve vs Blind Flange: Which Is Better When a Pipeline Needs to Be Opened Often?
Blind Valve vs Blind Flange: Which Is Better When a Pipeline Needs to Be Opened Often?
2026-09-30

When a pipeline must be opened and positively isolated often, a line blind valve is usually the better choice. It keeps the blind mechanism permanently installed and lets operators change between open and blocked positions without repeatedly removing a bolted end closure. A blind flange costs less and has fewer moving parts, but it is better suited to closing a pipe end that will remain closed for long periods.   This answer assumes that “blind flange” means a solid flange bolted to the end of a pipe or nozzle. A spectacle blind or a removable spade installed between two flanges is a different device, although it creates a similar solid-metal isolation barrier.   Frequent Opening Changes the Cost Calculation   The purchase price favors the blind flange. Its construction is simple, and maintenance is largely limited to checking the flange face, gasket, studs and nuts. If the closure will be disturbed only during an occasional turnaround, that simplicity is difficult to beat.   Repeated opening changes the picture. Removing a blind flange requires the line to be shut down, depressurized, drained or purged, and verified safe. The bolts must then be loosened, the flange supported and the sealing faces separated. Larger flanges may require lifting equipment. Reassembly introduces a new gasket, controlled bolt tightening and a leak test. None of these steps is unusual, but repeating them turns a low-cost component into a labor-intensive operating method.   A line blind valve also requires the line to be isolated and depressurized before changing position unless its approved design and operating procedure explicitly state otherwise. Its advantage is mechanical handling: the plate, spacer or sliding element remains captured in the body, and the mechanism separates, moves and reclamps the sealing faces. Manual gearing may suit moderate operating forces; electric, pneumatic or hydraulic actuation may be justified for large sizes or remote operation.   The Blind Valve Reduces Handling but Adds Equipment to Maintain   For frequent switching, a blind valve can shorten the task and reduce repeated handling of heavy plates, bolts and gaskets. Its open or closed position is normally visible from the external plate or position indication, which helps field verification. It also avoids repeatedly forcing connected piping apart to insert or remove a blind.   Those benefits come with additional maintenance. Guides, screws, gearboxes, hydraulic components, seals and interlocks must remain functional. Product deposits or corrosion can obstruct plate travel, while damaged sealing surfaces can prevent reliable reclamping. The installation therefore needs drainage, cleaning access and enough surrounding clearance to complete the full movement and service the mechanism.   A blind flange has no operating mechanism to seize. However, frequent removal can damage flange faces, stretch or corrode bolting, disturb pipe al...

 Gate Valve
加载中...

DN100 PN40 Gate Valve with Heat Jacket WCB DIN3352

This DN50 gate valve is one of the recent batch of our fresh heating jacketed gate valves whose diameter ranges from DN50 to DN150.

  • Payment:

    30% when order confirmed, 70% before shipment
  • Product Origin:

    China
  • Color:

    Customization
  • Shipping Port:

    Shanghai, China
  • Lead Time:

    30~60 days Ex Works after order confirmation
  • Material:

    WCB+STL
  • Method of Operation:

    Handwheel
Inquiry now
Product Detail

Quick Detail

Type

Gate Valve

Nominal Diameter

DN50-DN150

Nominal Pressure

PN40

Construction

Heat Jacket Type;OS&Y;Bolted Bonnet

Connection

RF

Design & Manufacture

DIN3352

F toF Dimension

DIN3202-F5

Flange End Dimensions

EN1092-1/B1

Test & Inspection

EN12266-1/2

Body Material

WCB+STL

Wedge Material

WCB+13Cr

Temp. Range

-29~425℃

Media

W.O.G.etc

 

Features

-HeatJacket-- prevents the valve body from beingcorroded by insulation media.
- Outside Screw and Yoke
- Bolted Bonnet and Pressure Seal
- Flexible and solid wedge, fully guided
- Welding seat rings or Renewable seat rings
- Rising stem and non-rising stem
- Available with gear operator
- Low torque design, smooth surface stem.

 

Technical Drawing


Dimension Check


Witnessing Tests


Packing



Product Application

Dervos valves can be widely used in varieties of industries, such as petrochemical,pipeline,oil & gas,marine,water treatment,power station industries and etc.



Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
Cast Steel Gate Valve Class 600
16 Inch Flanged Gate Valve WCB Rising Stem API 600

The 16 inch cast steel gate valve with gearbox and 600LB RF flange is designed as per API 600. The bolted bonnet gate valve features in rising stem, resilient wedge and metal seat. Quick Detail Type Gate Valve Size 16" Pressure Class600 Construction Bolted Bonnet, Rising Stem, OS&Y, Flexible Wedge, Metal Seat Connection RF Flange Operation Gearbox Design Code API 600 Face to Face ASME B16.10 Flange End ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material A216 WCB TrimMaterial Trim 5 Temperature Range -29℃~+425℃ Medium Water, Oil and Gas Origin China Dimension & Material Class 600 NPS in 2 2 1/2 3 4 6 8 10 12 14 16 18 20 24 DN mm 50 65 80 100 150 200 250 300 350 400 450 500 600 L-L1 (RF-BW) in 11.5 13 14 17 22 26 31 33 35 39 43 47 55 mm 292 330 356 432 559 660 787 838 889 991 1092 1194 1397 L2 (RTJ) in 11.625 13.125 14.125 17.125 22.125 26.125 31.125 33.125 35.125 39.125 43.125 47.25 55.375 mm 295 333 359 435 562 664 791 841 892 994 1095 1200 1407 H (OPEN) in 18.625 21.75 23.375 28 1/16 38 3/16 44 3/16 52.375 59 13/16 68.125 72.25 90.125 98 13/16 119 mm 474 553 593 713 970 1122 1330 1519 1730 1835 2290 2510 3022 W in 9.875 9.875 11 13/16 13.75 19 11/16 22 1/16 28.375 24 24 24 24 30 30 mm 250 250 300 350 500 560 720 610* 610* 610* 610* 760* 760* WT (kg) RF 41 58 88 131 253 413 623 784 1288 1820 2150 2540 4080 BW 35 50 68 104 208 328 496 637 1120 1448 1828 2201 3360 *Manual gear operator is recommended No Part Name Carbon steel to ASTM Alloy steel to ASTM Stainless steel to ASTM WCB LCB WC6 WC9  C5 CF8 CF8M CF3 CF3M 1 Body A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 2 Seat Ring A105 A350 LF2 A182 F11 A182 F22 A182 F5 A182 F304 A182 F316 A182 F304L A182 F316L 3 Wedge A216 WCB A350 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 4 Stem A182 F6 A182 F6 A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 5 Bonnet nut A194 2H A194 4 A194 7 A194 8 6 Bonnet bolt A193 B7 A320 L7 A193 B16 A193 B8 7 Gasket SS Spiral Wound graphite or SS Spiral Wound PTFE 8 Bonnet A216 WCB A352 LCB A217 WC6 A217 WC9 A217 C5 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 9 Backseat bushing A182 F6 A182 F6 A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 10 Stem packing Graphite or PTFE 11 Lantern A182 F6 A182 F6 A182 F304 A182 F304 A182 F304 A182 F304 A182 F316 A182 F304L A182 F316L 12 Gland Nut A194 2H A194 8 13 Gland Eyebolt A193 B7 A193 B8 14 PIN Carbon steel or Stainless Steel 15 Gland A182 F6 A182 F304 A182 F316 A182 F304L A182 F316L 16 Gland Flange A216 WCB A351 CF8 17 Stem Nut A439 D2 or B148-952A 18 Nipple Carbon steel or Stainless Steel 19 Retaining Nut Carbon steel 20 Hand Wheel Ductile Iron or carbon steel 21 Name Plate Stainless steel or Aluminum 22 H.W.Lock Nut Carbon steel

Handwheel 1.0619 Gate Valve
DN200 PN40 Bolt Bonnet Handwheel 1.0619 Gate Valve

Bolt bonnet Gate valve follow EN1984 design standard, raised face flanged connection, outside screw and yoke, handwheel operation, GP240GP body/bonnet/wedge material, F6a stem, metal seal/seated. Quick Detail  Type Gate Valve Size DN200 DesignPressure PN40 Construction Bolt Bonnet Gate Valve Connection Type Raised Face Flange Connection Operation Handwheel Design Code EN 1984 Face to Face DIN 3202 End Connection EN 1092-1 Test & Inspection  EN 12266-1 Body Material GP240GH Temperature Range -29~425℃ Application WOG

Gate Valve Handwheel BB OSY
Handwheel Gate Valve BB DN80 PN25 DIN1.0619

The DN80 PN25 gate valve is designed as per EN 1984. With common parts of a valve, like bolted bonnet, outside yoke and handwheel, its body is made of 1.0619 and 13Cr. Other parts including body, bonnet,seat and others are promised to be traceable.   Quick Detail Type Gate Valve Nominal Diameter DN80 NominalPressure PN25 Construction B.B ; OS&Y Connection RF Operation Handwheel Design & Manufacture EN 1984 End to End  DIN 3202 Flange End Dimension EN 1092-1 Test & Inspection  EN 12266-1 Temperature Range -29℃~+425℃ Body Material 1.0619 +STL Wedge Material 1.0619 +13Cr Media W.O.G. Company Brief Introduction  Specializing in valve industry over 10 years, Dervos becomes the leading vendor of gate, globe, check, ball, butterfly, plug valves and strainers. We serve oil and gas user such as LUKOIL, MOL, YPF with local partners.   Dervos show its advantages in: 1. Our partnerships with tens of stable suppliers allow us to provide customers with a wide range of high-quality products at a competitive price. 2. Each order is under strict quality control with inspection reports before delivery. 3. We value delivery time as much as our customers do. With the powerful purchasing system, we follow each order closely to secure on-time delivery. 4. One-stop solutions will be offered in a timely manner

WCB Gate Valve PN25 DN250 Bolted Bonnet RF
WCB Gate Valve PN25 DN250 Bolted Bonnet RF

The DN250 PN25 gate valve is designed as per DIN 3352. With common parts of a valve, like bolted bonnet, outside yoke and handwheel, its body is made of WCB and STL. Valve body, bonnet,seat and other parts are promised to be traceable.

20 Inch API600 NRS Gate Valve Solid Wedge FF BB Class150 Gearbox
20 Inch API600 NRS Gate Valve Solid Wedge FF BB Class150 Gearbox

This butch of gate valves are ranged from 3 inches to 32 inches. With non-rising gate valves and solid wedge, which are not regularly found in such big sized valves, these gate valves are quite special and reliable.

DN50 PN25 Double Heating Jacketed Gate Valve with OSY
DN50 PN25 Double Heating Jacketed Gate Valve with OSY

This DN50 gate valve is one of the recent batch of our fresh double heating jacketed gate valves whose diameter ranges from DN50 to DN250. The double jacket prevents the valve body from beingcorroded by insulation media.

Gate Valve
API Cast Steel NPS 8 Class150 Gate Valve OSY Handwheel

Dervos is a proud industrial API 600 cast steel gate valve manufacturer in China. Our stainless steel gate valves, carbon steel gate valves, and alloy steel gate valves are available in all trim configurations.

Gate Valve
Cast Steel DN400 PN16 Bare Stem Gate Valve BB RF OS&Y

DN400 PN16 gate valve is made according to EN1984 standard. The valve body is made of 1.0619 + STL. It has the structural characteristics of rising stem and structural length of 600mm.

Gate Valve
2" 600LB Cast Steel Gate Valve RTJ WCB Hand Wheel API600

2" 600LB gate valve is made according to API 600 standard. The valve body is made of ASTM A216 WCB. It has the structural characteristics of rising stem, bracket, full bore and elastic wedge. Its connection mode is RTJ. And it has hand wheel operation mode.

Gate Valve
12" 300LB Cast Steel Gate Valve RF WCB Gearbox API600

12" 300LB gate valve is made according to API600 standard. The valve body is made of ASTM A216 WCB. It has the structural characteristics of bolt cover, rising stem, elastic gate and full flow. Its connection mode is RF. And it has gearbox operation mode.

Cast Steel Gate Valve
6" 300LB Cast Steel Gate Valve BW API600 Handwheel LCB

6" 300LB gate valve is made according to API 600 standard. The valve body is made of A352 LCB. It has the structural characteristics of bolt cover, rising stem, OS&Y. Its connection mode is BW (SCH40). And it has handwheel operation mode.

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact