English

English

Get a Quote
Products

Hot Products

Company News

Three Common Causes of Valve Leakage and Emergency Remedies
Three Common Causes of Valve Leakage and Emergency Remedies
2025-05-28

In industrial production, valves are critical components for fluid control, and their sealing performance directly impacts system safety and stability. Leakage not only reduces operational efficiency but may also lead to fluid escape, posing serious safety risks. This article outlines three common causes of valve leakage and provides corresponding emergency response recommendations to help you quickly identify issues, take action, and mitigate risks.   1. Seal Surface Wear or Damage   Cause: During long-term operation, sealing pairs (e.g., valve seat and disc, valve ball and seat) suffer from media erosion, particle abrasion, or corrosion, leading to uneven sealing surfaces and resulting in minor or significant leakage. Emergency Measures: · Minor Leakage: Adjust compression force (e.g., tighten bonnet bolts) to temporarily reduce leakage. · Severe Leakage: Immediately shut down the system to replace or regrind sealing components; replace the entire valve if necessary. Prevention Recommendations: Conduct regular inspections, select valves with appropriate materials and wear-resistant designs. For media containing solid particles, use hard-sealing structures.   2. Packing Aging or Gland Loosening   Cause: Valve stem sealing uses packing materials (e.g., graphite, PTFE), which may age, dry, or crack over prolonged use. Temperature fluctuations can also cause gland loosening, leading to leakage at the packing box.  Emergency Measures: · Tighten packing gland bolts to increase packing compression. · If ineffective, add or replace packing material. · Avoid over-tightening to prevent increased operating torque or stem damage. Prevention Recommendations: Regularly replace packing; select materials compatible with the media and operating temperature. For critical equipment, consider spring-loaded packing glands.   3. Casting Defects or Corrosion Perforation in Valve Body/Bonnet   Cause: Some low-quality valves have casting defects such as sand holes or shrinkage cavities. Prolonged exposure to corrosive media can cause localized perforation of the valve body, resulting in uncontrollable leakage. Emergency Measures: · For small leaks, temporary repairs using metal adhesives or cold welding are possible. · Large-scale damage requires immediate valve replacement. · For high-pressure or toxic/hazardous media, no pressurized repair is allowed; follow shutdown procedures strictly.  Prevention Recommendations: Purchase valves from reputable manufacturers; use corrosion-resistant materials (e.g., 304/316L stainless steel). Perform regular wall thickness inspections on critical pipelines.   Common Questions & Answers (Q&A)   Q1: Can all valve leaks be fixed by replacing packing?A: No. Packing replacement is effective only when leakage is due to packing aging or gland loosening. If the leakage stems from seal surface or valve body damage, other me...

Can Oil Pass Through a Strainer? How Pre-Filtration Works in Lubrication Systems
Can Oil Pass Through a Strainer? How Pre-Filtration Works in Lubrication Systems
2025-05-20

In any efficient and reliable lubrication system, oil cleanliness is a core factor affecting equipment lifespan and operational efficiency. Strainers, as the front-line filtration devices in lubrication systems, play a critical role in pre-filtration. However, engineers and operators often raise the following questions: Can oil pass through strainers smoothly? What exactly is the function of a strainer? How does it differ from subsequent fine filters?   This article systematically explains the role of strainers in lubrication systems, covering their working principles, pre-filtration objectives, and practical applications across different systems.   1. Can Oil Pass Through a Strainer?   Answer: Yes, but with limitations.   (1) Strainer Structure Allows Oil Flow A strainer is fundamentally a low-precision filter made of stainless steel mesh or perforated metal plates. It features uniform pores, typically sized between 80–500 μm (micrometers), allowing most clean oil to flow through unimpeded.   (2) Contaminants Are Blocked Particles such as metal shavings, seal fragments, and carbon deposits in the oil are intercepted by the strainer, preventing them from entering the oil pump or other critical components.   (3) Oil Temperature and Viscosity Affect Flow Efficiency Low temperatures or high-viscosity oil may reduce flow rates or even cause blockages. This is one reason for low oil pressure during system startup.   2. Objectives and Significance of Pre-Filtration   (1) Protecting the Oil Pump Internal pump components (gears, impellers, or plungers) are highly sensitive to solid particles. Pre-filtration prevents particles from entering the pump, avoiding premature wear or seizure.   (2) Reducing Load on Primary Filters By intercepting large contaminants, strainers allow primary filters (e.g., oil filter cartridges) to focus on finer impurities, extending their service life and maintaining stable system flow.   (3) Lowering System Failure Rates Pre-filtration reduces risks such as pump failure, orifice blockages, and lubrication breakdown caused by foreign particles, enhancing overall system reliability.   3. Typical Applications of Pre-Filtration Devices   Application System Strainer Installation Position Strainer Type Internal Combustion Engine Lubrication Oil sump → Pump inlet Coarse metal strainer Hydraulic Systems Tank outlet → Pump suction port Suction strainer or basket strainer Turbine Lubrication Systems Pump inlet Dual-chamber switchable suction strainer Transmission/Clutch Systems Oil sump → Circulation pump inlet Perforated plate + magnetic strainer   4. Design and Usage Considerations for Strainers   (1) Pore Size Selection Must Align with System Precision Requirements 80–100 μm: Typical for engine oil systems. 150–300 μm: Used in hydraulic equipment. >400 μm:  Suitable for low-pressure or open-loop systems.   (2...

Are Ball Valves Suitable for Water Systems? A Practical Guide for Engineers & Installers
Are Ball Valves Suitable for Water Systems? A Practical Guide for Engineers & Installers
2025-04-30

Ball valves, with their simple structure, easy operation, and excellent sealing performance, have become widely used control components in both industrial and residential sectors. Particularly in water supply systems, an increasing number of engineers and installers are choosing ball valves as the primary fluid control device. But are ball valves truly suitable for water systems? How should one properly select and install them to ensure long-term stable operation? This article provides a comprehensive overview from the perspectives of structural principles, performance characteristics, and application recommendations. 1. Advantages of Ball Valves in Water Systems (1) Quick Opening and Closing Ball valves can complete the opening and closing operation with a simple 90° rotation, making them easy to operate and highly responsive—ideal for emergency situations or water systems that require frequent switching.   (2) Excellent Sealing Performance High-quality ball valves are equipped with PTFE or reinforced sealing materials, enabling zero leakage. They are particularly suitable for water supply systems in residential buildings, commercial complexes, and industrial facilities where sealing performance is critical.   (3) Compact Structure and Space-Saving Compared to gate valves or globe valves, ball valves occupy less space and offer flexible installation, making them ideal for water modules with high equipment integration.   (4) Strong Corrosion Resistance Ball valves made of stainless steel, brass, or plastic materials (such as UPVC) offer excellent corrosion resistance, capable of handling various water qualities (soft water, hard water, reclaimed water) and different additives.   2. Application Scenarios Analysis Ball valves are suitable for the following types of water systems: (1) Domestic Water Systems: Such as internal building water supply, point-of-use control for sanitary fixtures, and garden irrigation systems. (2) Industrial Water Systems: Such as cooling water circulation systems, boiler feedwater systems, and water supply for cleaning equipment. (3) Water Treatment Systems: Including reverse osmosis pretreatment, greywater recycling, and wastewater transfer processes. (4) Special Applications: High-pressure hot water systems or cleaning water containing chemical additives.   However, caution should be exercised in the following scenarios: (1) High-Frequency Modulation Conditions Standard ball valves are not suitable for precise flow regulation. It is recommended to use V-port ball valves or control-type electric ball valves. (2) Water Containing Sand, Gravel, or High Levels of Suspended Solids A Y-strainer should be installed to prevent particle blockage or damage to the sealing surfaces. (3) High-Temperature Hot Water Systems High-temperature ball valves with metal sealing structures should be selected to prevent seal aging and deformation.   3. Key Selection Criteria To ensure stable operation o...

DN100 WCB Ball Valve
加载中...

DIN Ball Valve DN100 PN16 WCB Floating Ball Heating Jacket

  • Payment:

    30% T/T When Order, 70% T/T Before Shipment
  • Color:

    Customization
  • Shipping Port:

    Shanghai
  • Lead Time:

    30~55 days Ex Works After Order Confirmation
  • Material:

    Cast Steel
  • Method of Operation:

    Lever
Inquiry now
Product Detail

DIN Ball Valve Full Pore RF Floaing Ball Fire Proof anti-static Lever WCB Body A105+ENP Ball 17-4PH Stem F304+Ni55 Seat X750 Spring Welding Flange Heating Jacket DN100 PN16


Quick Detail

Type

Ball Valve

Size

DN100

Design Pressure

PN16

Construction

Floating ball valve

ConnectionType

Raised Face Flange

OperationType

Lever

Body Material

WCB

BallMaterial

A105+Ni60

Stem Material

17-4PH

SeatMaterial

F304+Ni55

Design Code

EN12516-1

Face to Face Dimension

EN558-1

End Connection

EN1092-1 B1

Pressure & Temp

EN12266

Medium

Water, Oil and Gas

Origin

China

Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
Class 150 Floating Ball Valve
Aluminum Bronze Floating Ball Valve 1 Inch 150LB

The 1 inch floating type ball valve is made of aluminum bronze C95800. The reduced bore ball valve has lever operation, RF flange, two piece type body. Quick Detail Type Ball Valve Size 1" Pressure ANSI 150 Construction Floating Ball, 2-Piece Body, Side Entry, Reduced Bore Connection Flanged End Operation Lever Operation Body Material Aluminum Bronze ASTM B148 C95800 Media W.O.G Available Modifications for Ball Valve -Nominal Pressure -Valve Size -Reduced Port & Full Port -Material of Body, Ball, Stem, Seat, Packing, Bolt and Nut -Valve Operation (Lever, Gearbox, Pneumatic or Hydraulic or Electric Actuator) -End Connection Type -Available Extended Stem -Customized Coating & Packaging -Modifications of Drain Port Dervos Packaging Good packing means good first impression. Just imagine how do you feel differently when seeing two boxes below? And you will know the reason why in Dervos we value packaging so much. In Dervos, we make sure- 1.Every valve is clean and dry. What do we do? -Clean the valve before packing -Add anti-rust oil -Add flange cover 2.No damage to valves in delivery. How do we achieve this? -Fix the valve with iron wire -Separate the valve with soft material -Layer the valve with plywood 3.Strong box and clear shipping mark

Two Piece Cast Steel Ball Valve
Casting 2 Piece Ball Valve 4 Inch Class 150 Wrench

The 2 piece type floating ball valve has full port, fire safe design, anti blowout stem, ANSI 150 flange and lever operation. The carbon steel ball valve is designed with A216 WCB body, F316 stem and ball, PTFE soft seat. Quick Detail Type Ball Valve Size 4" Pressure 150 LB Construction Floating Type Ball, Two Piece Body, Full Bore Connection Raised Face Flange End Operation Wrench Operation Body Material Cast Steel WCB Trim Material SS316 &PTFE Design Standard API 6D Pressure & Temp Code ASME B16.34 Face to Face ASME B16.10 End Connection ASME B16.5 Inspection Code API 6D Temperature Range -29℃~+125℃ Media Water, oil and gas Material & Dimension No Part Name  Carbon steel to ASTM  Stainless Steel to ASTM WCB  LCB CF8 CF8M CF3 CF3M 1 Body  A216 WCB A352 LCB A351 CF8 A351 CF8M A351 CF3 A351 CF3M 2 Bonnet nut A194 2H A194 4 A194 8 3 Bonnet bolt A193 B7 A320 L7 A193 B8 4 Cap A216 WCB A352 LCB A351 CF8 A351 CF8M A351 CF3 A351 CF3M 5 Gasket SS Spiral Wound/graphite or SS Spiral Wound/PTFE 6 Ball  A105/Ep.Cr or F6 A182 F6 A351 CF8 A351 CF8M A351 CF3 A351 CF3M 7 Seat Ring RPTFE or POM 8 Small spring Stainless Steel 9 Small ball A182 F304  A182 F316L 10 Stem A182 F6 A182 F6 A182 F304 A182 F316 A182 F304L A182 F316L 11 Stem Seat PTFE 12 Stem Packing PTFE or Graphite 13 Gland A182 F6 A182 F304 A182 F316 A182 F304L A182 F316L 14 Gland Bolt A193 B7 A193 B8 15 Galnd Flange A216 WCB A351 CF8 16 Positioning Plate Steel 17 Wrentch A216 WCB The material is according to ASTM standard CLASS 150 DN mm 15 20 25 40 50 65 80 100 150 200 250 NPS in 0.5 0.75 1 1.5 2 2.5 3 4 6 8 10 L (RF) mm 108 117 127 165 178 191 203 229 394 457 533 in 4.25   4.6 5 6.5 7 7.5 8 9 15.5 18 21 L1 (BW) mm 140 152 165 190 216 241 283 305 457 521 559 in 5.5 6 6.5 7.48 8.5 9.5 11.13 12 18 20.5 22 L2 (RTJ) mm 119 129.7 139.7 178 191 203 216 241 406 470 546 in 4.69 5.11 5.5 6.9 7.5 8 8.5 9.5 16 18.5 21.5 H mm 66 74 87 105 132 152 182 215 250 285 495 in 2.6 2.9 3.48 4.2 5.28 6.08 7.28 8.6 10 11.4 19.5 Do(W) mm 130 130 160 230 400 400 600 850 1100 1500 *350 in 5.1 5.11 6.3 9 15.74 15.74 23.62 33.46 43.3 59 13.8 RF(Kg)   2.3 3 4.5 7 15 20 25 40 97 160 240 BW(Kg)   2.0 2.5 3.8 5.8 12 17 21 36 92.8 154 227 *Worm Gear or Electric actuator operated Special Tests & Inspections In addition to regular hydraulic testing and air testing, Dervos could also do specials test as per clients’ requests, such as PT test, RT test, UT test, cryogenic test, low leakage test, fire proof test, and hardness test and so on. 

API 6D Ball Valve Manufacturer
API 6D Floating Ball Valve 2 Inch 600LB Extended Stem A105

API 6D ball valve is designed with an extended stem for special use, like underground ball valve or low temperature application. The length of the extended stem can be customized as per client's request. Quick Detail Type Ball Valve Size 2 Inch Pressure Class 600 Construction Split Body, Side Entry, Floating Type, Firesafe Design, Antistatic System, Anti-Blowout Stem, Extended Bonnet Connection RF Flange Operation Mode Lever Body Material A105N Trim Material SS304 Ball and Stem, RPTFE Seat Design & Manufacture API 6D Pressure & Temp Code ASME B16.34 End to End ASME B16.10 End Connection ASME B16.5 Inspection API 6D, API 598 Temperature Range -29℃~+200℃ Medium Oil, Water, Gas QC Process in Dervos Casting inspection: We can find out the raw material’s problem, such as shoddy casting, unqualified wall thickness, chemical composition and so on, which ensure that you will not be cheated.   Machining Inspection: -Ensure machining accuracy -Find out machining mistake as early as possible, to win more time for repairing, remaking Final Inspection: -Final inspection activities include document and QC record review, visual examination, dimension check, pressure test, painting and packing check -Save time and cost: you don’t need to come and inspect in person and all the documents could be provided as proof. Inspection report will be provided free of charge including:   -EN 10204 3.1 Mill Test Certificate -Inspection Report, showing the whole inspection process

 Forged Steel A105 NPT Ball Valve
DN25 PN100 Forged Steel A105 NPT Ball Valve

DN25 PN100 Forged Steel A105 NPT Connection Way 2 Pieces Construction Full Pore Lever Operation Floating Ball Fire Safety Body and Bonnet A105 Ball a182 F304 Seat Ring PTFE Stem A182 F304 Stem O Ring Viton Packing Graphite Gland Stainless Steel Design and Manufacture ASME B16.34 Face to Face Design Manufacture Standard Manufacture Standard Screw and Dimension ANSI B1.20.1 Inspection and Test API598 Fire Safety Design API 607  Quick Detail Type Ball Valve Size DN25 Pressure PN100 Construction 2 Pieces Connection NPT Operation Mode Lever Body Material A105 Cover A105 Design & Manufacture ASME B16.34 End to End ASME B16.10 End Connection  ANSI B1.20.1 Inspection API 598 Temperature Range -29℃~+538℃ Medium Oil, Water, Gas

2 Piece Floating Ball Valve WCB 150LB 4Inch Reduced Bore
2 Piece Floating Ball Valve WCB 150LB 4Inch Reduced Bore

The 2-piece floating ball valve, made in accordance with API 6A, has a design of reduced bore, fire safe design, anti blowout stem. With the RPTFE seat and PTFE O ring, the 4 inch WCB valve is certificate to serve you.

JIS 2 Piece Floating Ball Valve RF×NPT 25A 16K
JIS 2 Piece Floating Ball Valve RF×NPT 25A 16K

This ball valve, designed as per ASME B16.34, features two different connection ways--one side for RF and the other side NPT. The valve with floating ball, PTFE seat, SCS13 body and other features has an excellent sealing performance.

2 Inch 600LB API6D Ball Valve RF Full Bore 2 piece type
2 Inch 600LB API6D Ball Valve RF Full Bore 2 piece type

The forged steel ball valve is made of A105 body and 17-4PH trim with RTJ flange end and lever operation. This floating ball valve features reliable sealing performance and easy operation.

Stainless Steel 2 Pieces Type Ball Valve 1-1/2 Inch 800LB
Stainless Steel 2 Pieces Type Ball Valve 1-1/2 Inch 800LB

Made of F316, the floating ball valve is designed under the code of ASME B16.34. The valve consists of two-piece body, floating ball, lever operation, with good reliable sealing performance and small torque.

1Inch Three-Piece Manual Ball Valve Full Bore
1Inch Three-Piece Manual Ball Valve Full Bore

Made of CF8M, the 2 PC valve is designed according to ASME B16.34. Mixed with 15 percent of fibreglass, the RPTFE seat of the valve is more eligible to bear high temperature and high corrosive working condition.

Flanged End Ball Valve
Flanged End Ball Valve, ASTM A350 LF6, CL600, 1/2 Inch, Two Piece

China Flanged End Ball Valve Producer,Dervos Offers Flanged End Ball Valve, ASTM A350 LF6, Class 600, 1/2 Inch, Two Piece, Forging, API 608, BS 5351, ASME B16.34.

Floating Ball Valve
2 inch CL300 2PC Floating Ball Valve Full Bore 1/2" NPT(F) X 2" RF

The 3000LB ball valve, made of F316 or F316L, has an asymmetric end structure, a end is NPT while another RF. It is capable to work under -29℃~150℃.

Ball Valve
3/4 inch ANSI Class 150 Floating Ball Valve Stainless Steel

Made as per API6D, the two pc floating ball valve, 3/4inch and 150LB, has different ends.Find your floating ball valve or other valves easily in Dervos.

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact