English

English

Get a Quote
Products

Hot Products

Company News

Reflections on the Fire at Russia’s Amur Gas Chemical Complex — Valve Safety Analysis for the Auxiliary Process Section of a Cracking Unit
Reflections on the Fire at Russia’s Amur Gas Chemical Complex — Valve Safety Analysis for the Auxiliary Process Section of a Cracking Unit
2026-08-27

Fact Statement: The fire is still under investigation, and publicly available information has not yet confirmed the exact cause of the accident. Therefore, this article does not analyze the cause of the accident, nor does it attribute the accident to any specific valve, piping component, or equipment. Instead, it focuses on valve safety issues commonly involved in the commissioning of large-scale chemical facilities.   On August 25, 2026, a serious fire occurred at the Amur Gas Chemical Complex (AGCC) in the Amur Region of Russia’s Far East. As of August 26, the accident had resulted in 7 deaths, 152 injuries, and 9 people missing.   According to an official statement from AGCC, the fire occurred in the auxiliary process section of the plant’s pyrolysis unit, while the main project equipment was not damaged. This accident is deeply distressing and once again reminds us that, in natural gas chemical projects, the safety of auxiliary process sections, particularly the reliability of valves, is by no means an “auxiliary” issue.   1. What Is the Auxiliary Process Section of a Cracking Unit?   An ethylene cracking unit is an extremely complex system with highly demanding process requirements. The cracking furnace is the heart of the unit, where natural gas or naphtha is cracked at temperatures above 800°C into basic chemical feedstocks such as ethylene and propylene.   The Auxiliary Technological Section, although not located at the center of the high-temperature reaction like the cracking furnace, is responsible for providing stable utilities and various auxiliary media for the entire unit, ensuring the continuous and safe operation of the main unit.   The auxiliary process section mainly includes the following seven subsystems:   1. Fuel Gas/Fuel Oil System: This includes fuel gas buffer vessels, knockout drums, fuel oil pumps, strainers, and burners, and is responsible for supplying stable and clean fuel to the cracking furnace. 2. Steam System: The core equipment is the Steam Drum, which generates and distributes the dilution steam, high-pressure steam, and other steam required by the unit. 3. Feedwater and Condensate System: This includes deaerators, boiler feedwater pumps, condensate recovery tanks, and other equipment responsible for supplying and treating qualified water for the steam system. 4. Compression and Refrigeration System: This includes multistage compressors, intercoolers, separators, and refrigeration compressors, which are used to compress and cool cracked gas and provide refrigeration for downstream separation. 5. Drying and Purification System: This mainly consists of molecular sieve dryers used to remove trace moisture from cracked gas and prevent freezing and blockage of downstream equipment at low temperatures. 6. Relief and Flare System: This includes flare knockout drums, flare tips, and other equipment used to safely burn and dispose of combustib...

Manual, Gear, or Hydraulic Line Blind Valve: Which Operation Type Fits Your Pipeline Shutdown?
Manual, Gear, or Hydraulic Line Blind Valve: Which Operation Type Fits Your Pipeline Shutdown?
2026-08-21

Operation Type Is a Shutdown Decision   A line blind valve is chosen for positive isolation, but the operation type decides how practical that isolation will be during a shutdown. Manual, gear-operated, and hydraulic designs can all move the blind between open and closed positions, yet they do not create the same workload, speed, or safety margin. For shutdown planning, the right question is not only “Can the valve isolate the line?” It is “Can operators switch, verify, lock, and return the valve to service safely within the shutdown window?”   Manual Operation: Simple, but Limited   Manual operation is usually suitable for smaller line blind valves, lower pressure classes, infrequent switching, and sites where operators have clear access around the valve. It keeps the design simple and avoids dependence on hydraulic power units or control systems. The limitation is physical effort. As size, pressure class, seal load, and plate weight increase, manual operation becomes slower and more exposed to human error. If several operators, lifting tools, or extended handling time are needed, the valve may no longer be a good fit for a tight shutdown schedule.   Manual operation is best treated as a low-complexity option for manageable sizes and low switching frequency.   Gear Operation: Better Control for Medium-Duty Shutdowns   A gear-operated blind valve gives operators more mechanical advantage and better control than direct manual operation. It is useful when the valve is too large or stiff for simple manual switching, but the site does not justify a hydraulic system. Gear operation often fits plant shutdowns where isolation is planned, access is available, and switching speed matters but is not the only priority. It can reduce operator strain and make the changeover more predictable.   The buyer should still review gearbox location, handwheel access, operation turns, torque, locking method, and position indication. A gear operator that cannot be reached safely during shutdown is not a good solution, even if the valve design is correct.   Hydraulic Operation: For Large, High-Pressure, or Time-Critical Lines   Hydraulic operation is usually considered when the pipeline isolation valve is large, high-pressure, frequently switched, or located in a difficult operating area. It can reduce manual handling, shorten changeover time, and improve control during planned isolation. This makes hydraulic line blind valves attractive for refineries, gas systems, terminals, high-temperature service, and shutdowns where every hour of downtime has a cost. Hydraulic operation can also support safer distance between personnel and the moving mechanism, depending on the control arrangement.   The tradeoff is system complexity. Hydraulic cylinders, hoses, power units, seals, and controls need inspection and maintenance. Buyers should ask how the valve is operated if hydraulic power is lost, how the pos...

Sliding vs Swing Type Line Blind Valve: How to Choose the Right Design for Pipeline Isolation
Sliding vs Swing Type Line Blind Valve: How to Choose the Right Design for Pipeline Isolation
2026-08-14

Both sliding and swing type line blind valves are used for the same core purpose: positive isolation. In the closed position, a solid blind plate  blocks the pipeline bore, giving operators a visible and mechanical isolation method before maintenance, inspection, shutdown work, or media changeover.   The difference is not whether one can isolate and the other cannot. The real question is how the valve moves, how much space the site has, how often the line must be switched, and how difficult the operation will be under pressure, temperature, and site-access limits.   A sliding type line blind valve moves the blind plate laterally. This design is often useful where side clearance is available but swing clearance is limited. A swing type line blind valve rotates the blind plate into or out of the flow path. It is often selected where fast, clear changeover is needed and the installation area allows the plate to swing.   Selection Factor Sliding Type Line Blind Valve Swing Type Line Blind Valve Structure Blind plate slides sideways between open and closed positions Blind plate rotates or swings between open and closed positions Operation Often gear, hydraulic, pneumatic, or electric assisted for easier plate movement Manual, gear, hydraulic, pneumatic, or electric operation depending on size and class Maintenance Sliding tracks, sealing surfaces, and drive parts should be checked regularly Pivot, locking parts, sealing surfaces, and drive parts need inspection Space Requirement Usually better when swing radius is restricted, but needs side travel space Needs enough swing clearance around the pipeline Suitable Service Frequent switching, compact plant layout, limited swing area Clear operation path, quick changeover, maintenance isolation, oil, gas, steam, or chemical lines   For compact plants, pipe racks, or areas with nearby equipment, sliding type designs may be easier to arrange. Their lateral movement can avoid the large arc required by a swing plate. This is one reason sliding line blinds are often considered when installation space is a serious constraint.   Swing type designs are often preferred when the site has enough clearance and operators want a simple visual change between open and blind positions. For large sizes or higher pressure classes, the operation method becomes important. Gear, hydraulic, pneumatic, or electric operation can reduce manual effort and improve safety.   When choosing between the two, start with the site layout. If the valve cannot physically move through its full travel, the design is wrong no matter how good the specification looks. Then check pressure class, medium, temperature, material, sealing type, switching frequency, and required test standard.   For high-temperature steam, hot oil, gas, toxic media, or flammable service, do not select only by valve type. Confirm body material, blind plate material, seal material, operating torque, ...

Check Valve
加载中...

Single Disc Wafer Check Valve 6 Inch 150LB

The 6 inch 150 LB single disc wafer check valve, designed per API 594, has one disc and wafer connection. It will have the best performance under -29 to 350 Celsius degree.

  • Payment:

    30% when order confirmed, 70% before shipment
  • Product Origin:

    China
  • Color:

    Customization
  • Shipping Port:

    Shanghai, China
  • Lead Time:

    30~60 days Ex Works after order confirmation
  • Material:

    ASTM A105
Inquiry now
Product Detail

Quick Detail

Type

Check Valve ( Non-return Valve)

Nominal Diameter

6’’

Nominal Pressure

150LB

Construction

Swing Type

Connection

WAFER

Design & Manufacture

API 594

End to End 

ASME B16.10

Test & Inspection 

API 598

Body Material

ASTM A105

Media

W.O.G.


QC Process in Dervos

Casting inspection:

We can find out the raw material’s problem, such as shoddy casting, unqualified wall thickness and chemical composition and so on, which ensure that you will not be cheated.  

 

Machining Inspection:

--Ensure machining accuracy

--Find out machining mistake as early as possible, to win more time for repairing, remaking

 

Final Inspection:

--Final inspection activities include document and QC record review, visual examination, dimension check, pressure test, painting and packing check

--Save time and cost: You don’t need to come and inspect in person and all the documents could be provided as proof.

 

Inspection report will be provided free of charge including:  

--EN 10204 3.1 Mill Test Certificate

--Inspection Report, showing the whole inspection process

Leave A Message

If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Related Products
Dual Disc Lug Check Valve 150 LB
Duplex SS Check Valve Lug Type Dual Plate 8 Inch Class 150

The 8 inch 150 LB dual disc non return check valve, designed per API 594, has dual plate and lug connection. The retainerless dual  plate check valve is made of duplex stainless steel 4A as its body and trim material. Quick Detail Type Check Valve Size 8'' DesignPressure Class 150 Construction Dual Plate Type, Retainerless Connection Lug Type Design & Manufacture API 594 End to End ASME B16.10 Connection ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material Duplex Stainless Steel 4A Trim Material Duplex Stainless Steel Media W.O.G. Design Feature 1.Shor face to face dimension 2.Small in size with light weight 3.Swift close of disc with small water hammer 4.Vertically or horizontally installed 5.Smooth flow passway with small flow resistance 6.Long cycle life and high reliability

6 Inch Dual Check Valve
Wafer Check Valve AL Bronze C95800 Dual Disc 6 Inch

The dual disc wafer check valve is designed as per API 594 and tested per API 598. The bronze non return valve is applicable for sea water. Quick Detail Type Check Valve Size 6'' DesignPressure Class 150 Construction Dual Plate Type, With Retainer Connection Wafer Type Design & Manufacture API 594 End to End ASME B16.10 Connection ASME B16.5 Pressure & Temp ASME B16.34 Test & Inspection API 598 Body Material Aluminum Bronze C95800 Trim Material Aluminum Bronze C95800 Media W.O.G. Dervos Inspection after Valve Assembly Valve quality is one of perspectives we care about most. In Dervos, quality control starts from raw material, machining, assembly to pre-shipment inspection. After assembly, the quality checking team will do visual checking, dimension checking, hydraulic testing and air testing. Every order must pass the test per inspection standards. Otherwise our quality checking team will not release the shipment. Inspection Reports Documents can be used to prove how we control valve quality. Along with every order, Dervos will provide clients with an inspection report & a 3.1 mill test report for free. In Dervos inspection report, you will see the actual results of dimension checking and pressure testing along with painting and packing picture. All these info are shown through data and clear pictures.   In 3.1 mill test report, we will show you the chemical composition, mechanical property and heat number for valve body, bonnet, stem, disc and so on.  

Double Disc Check Valve
Double Disc Check Valve DN3202 PN25 DN100 CF8

The double- disc check valve, made of CF8 stainless steel, has excellent resistance to corrosion. Designed in accordance with DIN 3202, the check valve is about to connect to pipes with WAFER. Quick Detail Type Check Valve Nominal Diameter DN100 NominalPressure PN25 Construction Double disc/ Dual Plate Connection Wafer Type Design & Manufacture DIN 3202 End to End  DIN 3202 Flange End Dimension DIN 2401 Test & Inspection  API 598 Temperature Range -29℃~+425℃ Body Material A351 CF8 Wedge Material A351 CF8 Media W.O.G. Dervos Packaging Good packing means good first impression. Just imagine how do you feel differently when seeing two boxes below? And you will know the reason why in Dervos we value packaging so much. In Dervos, we make sure- 1. Every valve isclean and dry. What do we do? -Clean the valve before packing -Add anti-rust oil -Add flange cover 2. No damageto valves in delivery. How do we achieve this? -Fix the valve with iron wire -Separate the valve with soft material -Layer the valve with plywood 3. Strong box and clear shipping mark

Retainerless Wafer Lug type Check Valve 6'' 900LB
Retainerless Wafer Lug type Check Valve 6'' 900LB

The 6 inch Wafer check valve is made in strict accordance to API 594. The body material LCC make sure the lug type valve is capable to handle harsh environment, and the INCONEL-X 750 spring promise the valve a long service life.

Dual Plate Wafer Check Valve API 594 DN250 10K
Dual Plate Wafer Check Valve API 594 DN250 10K

The double-disc check valve, made of A395 D1, has excellent resistance to corrosion. Designed in accordance with API594, the check valve is connected to pipes with WAFER. This valve is eligible to be put in marine working conditions.

API594 Dual-Plate WAFER Check Valve WCB 300LB
API594 Dual-Plate WAFER Check Valve WCB 300LB

The 10 inch Dual-Plate WAFER Check Valve is made of WCB and is eligible to be put under pressure up to 30LB. All Dervos check valves are tested to API 598 and must meet or exceed all applicable API, ANSI and ASTM Standards.

DIN Single Plate WAFER Check Valve DN80 PN40
DIN Single Plate WAFER Check Valve DN80 PN40

The single-disc check valve, made of CF8, has excellent resistance to corrosion. Designed in accordance with API594, the valve is of a WAFER type.

Wafer Check Valve
3" 150LB Dual Plate Wafer Check Valve API594 A995 5A

3" 150LB wafer check valve is made according to API594 standard. The valve body is made of A995 5A. It has the structural characteristics of built-in type and dual plate. Its connection mode is wafer type.

Wafer Check Valve
CF8M 20" 150LB Dual Plate Wafer Check Valve API594

20" 150LB wafer check valve is made according to API594 standard. The valve body is made of A351 CF8M. It has dual plate and built-in type structural features. Its connection mode is Wafer RF.

Wafer Check Valve
20" 300LB Dual Plate Wafer Check Valve WCB API 594

20" 300LB wafer check valve is made according to API 594 standard. The valve body is made of WCB. It has the structural characteristics of double plate and built-in type. Its connection mode is wafer type.

Wafer Check Valve
API594 3" 150LB Dual Plate Wafer Check Valve API598 LCC

3" 150LB wafer check valve is made according to API594 standard. The valve body is made of A352 LCC + 316. It has the structural characteristics of double plate and built-in type. Its connection mode is wafer type.

Leave a message

    If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

about

contact